AAPM Task Group Report 307: use of EPIDs for patient‐specific IMRT and VMAT QA

N Dogan, BJ Mijnheer, K Padgett… - Medical …, 2023 - Wiley Online Library
Purpose Electronic portal imaging devices (EPIDs) have been widely utilized for patient‐
specific quality assurance (PSQA) and their use for transit dosimetry applications is …

Estimating dose delivery accuracy in stereotactic body radiation therapy: a review of in-vivo measurement methods

M Esposito, E Villaggi, S Bresciani, S Cilla… - Radiotherapy and …, 2020 - Elsevier
Stereotactic body radiation therapy (SBRT) has been recognized as a standard treatment
option for many anatomical sites. Sophisticated radiation therapy techniques have been …

Improving dose delivery accuracy with EPID in vivo dosimetry: results from a multicenter study

M Esposito, A Piermattei, S Bresciani… - Strahlentherapie und …, 2021 - Springer
Purpose To investigate critical aspects and effectiveness of in vivo dosimetry (IVD) tests
obtained by an electronic portal imaging device (EPID) in a multicenter and multisystem …

IPEM topical report: Guidance for the clinical implementation of online treatment monitoring solutions for IMRT/VMAT

S Stevens, S Moloney, A Blackmore… - Physics in Medicine …, 2023 - iopscience.iop.org
This report provides guidance for the implementation of online treatment monitoring (OTM)
solutions in radiotherapy (RT), with a focus on modulated treatments. Support is provided …

Clinical implementation of 3D in vivo dosimetry for abdominal and pelvic stereotactic treatments

M Esposito, A Ghirelli, S Pini, P Alpi, R Barca… - Radiotherapy and …, 2021 - Elsevier
Purpose To analyze results from three years of in vivo transit EPID dosimetry of abdominal
and pelvic stereotactic radiotherapy and to establish tolerance levels for routine clinical use …

[HTML][HTML] A validation method for EPID in vivo dosimetry algorithms

M Esposito, L Marrazzo, E Vanzi, S Russo, S Pallotta… - Applied Sciences, 2021 - mdpi.com
Featured Application Transit dosimetry, with Electronic Portal Imaging Device (EPID), is a
powerful tool for in vivo dosimetry (IVD). Despite its wide availability and its simplicity of use …

Feasibility study of an electronic portal imaging based in vivo dose verification system for prostate stereotactic body radiotherapy

Y Yedekci, F Biltekin, G Ozyigit - Physica Medica, 2019 - Elsevier
Purpose We evaluated the feasibility of electronic portal imaging based 3D in-vivo dosimetry
for stereotactic body radiation therapy (SBRT) technique in prostate cancer. Methods and …

Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy

S Cilla, A Ianiro, M Craus, P Viola… - Journal of Applied …, 2019 - Wiley Online Library
We evaluated an EPID‐based in‐vivo dosimetry (IVD) method for the dose verification and
the treatment reproducibility of lung SBRT‐VMAT treatments in clinical routine. Ten patients …

EPID-based 3D dosimetry for pre-treatment FFF VMAT stereotactic body radiotherapy plan verification using dosimetry CheckTM

A Chendi, A Botti, M Orlandi, R Sghedoni, M Iori… - Physica Medica, 2021 - Elsevier
Abstract Purpose The software Dosimetry Check (DC) reconstructs the 3D dose distribution
on CT images data set by using EPID measured signal. This study aimed to evaluate DC for …

Comparison of three-dimensional patient-specific dosimetry systems with delivery errors: Toward a new synchronous measurement method

A Chen, J Zhu, N Wang, L Chen, L Chen - Physica Medica, 2021 - Elsevier
Purpose This study proposed a synchronous measurement method for patient-specific
dosimetry using two three-dimensional dose verification systems with delivery errors …