Tissue characterization

RC Chivers - Ultrasound in medicine & biology, 1981 - Elsevier
The term “tissue characterization” covers a range of meanings from qualitative assesments
to scientific measurements. From the vast literature available the selection presented is used …

Experimental study of the acoustical properties of polymers utilized to construct PVDF ultrasonic transducers and the acousto-electric properties of PVDF and P (VDF …

PE Bloomfield, WJ Lo, PA Lewin - IEEE transactions on …, 2000 - ieeexplore.ieee.org
Several acoustic transmission and reflection technique measurements were carried out to
determine mechanical properties (acoustic attenuation and velocity) versus frequency of …

Temperature and frequency dependence of ultrasonic attenuation in selected tissues

PM Gammell, DH Le Croissette, RC Heyser - Ultrasound in medicine & …, 1979 - Elsevier
Ultrasonic attenuation over the frequency range of 1.5–10 MHz has been measured as a
function of temperature for porcine liver, backfat, kidney and spleen as well as for a single …

Improved ultrasonic detection using the analytic signal magnitude

PM Gammell - Ultrasonics, 1981 - Elsevier
An alternative to rectification is proposed for detection of an ultrasonic signal for medical or
non-destructive evaluation applications. With this technique the envelope of the ultrasonic …

Application of time-delay spectrometry for calibration of ultrasonic transducers

PC Pederson, PA Lewin… - IEEE transactions on …, 1988 - ieeexplore.ieee.org
Time-delay spectrometry (TDS) can conveniently be used for calibration and performance
evaluation of piezoelectric electroacoustic transducers. The main emphasis of the work …

Effects of diffraction on measurements of the frequency-dependent ultrasonic attenuation

M O'donnell - IEEE Transactions on Biomedical Engineering, 1983 - ieeexplore.ieee.org
Using a one-dimensional model of wave propagation, the ultrasonic attenuation can be
estimimated from spectral analysis of RF A-scans. The results of computer modeling studies …

Techniques of hydrophone calibration

ME Schafer - Ultrasonic exposimetry, 2020 - taylorfrancis.com
This chapter presents a number of calibration techniques for hydrophones used in ultrasonic
exposimetry. The topic of hydrophone calibration methods is central to ultrasonic …

Time-delay spectrometry for ultrasonic transducer characterisation

RC Chivers - Journal of Physics E: Scientific Instruments, 1986 - iopscience.iop.org
The use of the technique of time-delay spectrometry in ultrasonic transducer characterisation
is described for both transmitters and receivers. The principles of the technique, the choice …

Attenuation and backscattering of ultrasound in freshly excised animal tissues

MP Kadaba, PK Bhagat, VC Wu - IEEE Transactions on …, 1980 - ieeexplore.ieee.org
A modified version of pulse echo technique was used to measure the attenuation a and
backscattering α bs coefficient of ultrasound (frequency range 1-10 MHz) in freshly excised …

Medical ultrasound imager based on time delay spectrometry

RC Heyser, JD Hestenes, JA Rooney, PM Gammell… - Ultrasonics, 1989 - Elsevier
A reflection mode proof-of-concept medical ultrasound imager based on time delay
spectrometry has been developed and tested. The system uses a broad band swept …