Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the ADVANCE III …

M Gasparini, A Proclemer, C Klersy, A Kloppe, M Lunati… - Jama, 2013 - jamanetwork.com
Importance Using more intervals to detect ventricular tachyarrhythmias has been associated
with reducing unnecessary implantable cardioverter-defibrillator (ICD) therapies. Objective …

Use of a discrimination algorithm to reduce inappropriate shocks with a subcutaneous implantable cardioverter-defibrillator

MR Gold, R Weiss, DAMJ Theuns, W Smith, A Leon… - Heart Rhythm, 2014 - Elsevier
Background The subcutaneous implantable cardioverter-defibrillator system (S-ICD) uses a
novel detection algorithm previously shown to discriminate induced tachyarrhythmias …

Efficacy of long detection interval implantable cardioverter-defibrillator settings in secondary prevention population: data from the Avoid Delivering Therapies for …

A Kloppe, A Proclemer, A Arenal, M Lunati… - Circulation, 2014 - Am Heart Assoc
Background—Three trials demonstrated recently that a long detection window reduces
implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. Avoid …

Long detection programming in single-chamber defibrillators reduces unnecessary therapies and mortality: the ADVANCE III trial

M Gasparini, MG Lunati, A Proclemer, A Arenal… - JACC: Clinical …, 2017 - jacc.org
Objectives: This study sought to evaluate the effects of programming a long detection in
single-chamber (VVI) implantable cardioverter-defibrillators (ICDs) in the multicenter …

[HTML][HTML] Prospective multicenter randomized trial of fast ventricular tachycardia termination by prolonged versus conventional anti-tachyarrhythmia burst pacing in …

M Santini, M Lunati, P Defaye, J Mermi… - Journal of interventional …, 2010 - Springer
Purpose The purpose of the trial was to quantify and compare the efficacy of two different
sequences of burst anti-tachycardia pacing (ATP) strategies for the termination of fast …

Different impact of long-detection interval and anti-tachycardia pacing in reducing unnecessary shocks: data from the ADVANCE III trial

A Arenal, A Proclemer, A Kloppe, M Lunati… - EP …, 2016 - academic.oup.com
Aims A long-detection interval (LDI)(30/40 intervals) has been proved to be superior to a
standard-detection interval (SDI)(18/24 intervals) in terms of reducing unnecessary …

Initial clinical experience with a new automated antitachycardia pacing algorithm: feasibility and safety in an ambulatory patient cohort

R Yee, JD Fisher, U Birgersdotter-Green… - Circulation …, 2017 - Am Heart Assoc
Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD)
decreases patient shock burden but has recognized limitations. A new automated ATP …

Implantable cardioverter defibrillator harm?

M Gasparini, S Nisam - Europace, 2012 - academic.oup.com
Despite the general acceptance of implantable cardioverter defibrillator (ICD) therapy
[including cardiac resynchronization therapy defibrillator (CRT-D)] among cardiologists …

Results of ENHANCED implantable cardioverter defibrillator programming to reduce therapies and improve quality of life (from the ENHANCED-ICD study)

MH Mastenbroek, SS Pedersen, I van der Tweel… - The American Journal of …, 2016 - Elsevier
Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and
programming strategies have significantly reduced the incidence of inappropriate shocks …

Temporal trends over a decade of defibrillator therapy for primary prevention in community practice

S Boveda, K Narayanan, S Jacob… - Journal of …, 2017 - Wiley Online Library
Temporal Trends Over a Decade of Defibrillator Therapy Background Technology and
clinical practice surrounding the use of the primary prevention implantable cardioverter …