A mechanics-based perspective on the function of human sphincters during functional luminal imaging probe manometry

G Elisha, S Halder, DA Carlson… - Journal of …, 2024 - asmedigitalcollection.asme.org
Functional luminal imaging probe (FLIP) is used to measure cross-sectional area (CSA) and
pressure at sphincters. It consists of a catheter surrounded by a fluid filled cylindrical bag …

Enhancing Chicago Classification diagnoses with functional lumen imaging probe—mechanics (FLIP‐MECH)

S Halder, J Yamasaki, X Liu, DA Carlson… - …, 2024 - Wiley Online Library
Background Esophageal motility disorders can be diagnosed by either high‐resolution
manometry (HRM) or the functional lumen imaging probe (FLIP) but there is no systematic …

Neurological disorders leading to mechanical dysfunction of the esophagus: an emergent behavior of a neuromechanical dynamical system

G Elisha, S Halder, X Liu, DA Carlson… - arXiv preprint arXiv …, 2024 - arxiv.org
An understanding how neurological disorders lead to mechanical dysfunction of the
esophagus requires knowledge of the neural circuit of the enteric nervous system …