Assessment of the relationships between myocardial contractility and infarct tissue revealed by serial magnetic resonance imaging in patients with acute myocardial …

C McComb, D Carrick, JD McClure… - The international journal …, 2015 - Springer
Imaging changes in left ventricular (LV) volumes during the cardiac cycle and LV ejection
fraction do not provide information on regional contractility. Displacement ENcoding with …

[HTML][HTML] Clinical experience of strain imaging using DENSE for detecting infarcted cardiac segments

J Kihlberg, H Haraldsson, A Sigfridsson… - Journal of …, 2015 - Elsevier
Background We hypothesised that myocardial deformation determined with magnetic
resonance imaging (MRI) will detect myocardial scar. Methods Displacement Encoding with …

[图书][B] Biomedical signals, imaging, and informatics

JD Bronzino, DR Peterson - 2015 - api.taylorfrancis.com
During the past eight years since the publication of the third edition—a three-volume set—of
The Biomedical Engineering Handbook, the eld of biomedical engineering has continued to …

[图书][B] Heart Mechanics: Magnetic Resonance Imaging—Advanced Techniques, Clinical Applications, and Future Trends

ESH Ibrahim - 2017 - taylorfrancis.com
Based on research and clinical trials, this book details the latest research in magnetic
resonance imaging (MRI) tagging technology related to heart mechanics. It covers clinical …

Incompressible deformation estimation algorithm (IDEA) from tagged MR images

X Liu, KZ Abd-Elmoniem, M Stone… - IEEE transactions on …, 2011 - ieeexplore.ieee.org
Measuring the 3D motion of muscular tissues, eg, the heart or the tongue, using magnetic
resonance (MR) tagging is typically carried out by interpolating the 2D motion information …

Threedimensional regional strain computation method with displacement encoding with stimulated echoes (DENSE) in nonischemic, nonvalvular dilated …

J Kar, AK Knutsen, BP Cupps, X Zhong… - Journal of Magnetic …, 2015 - Wiley Online Library
Purpose Fast cine displacement encoding with stimulated echoes (DENSE) MR has higher
spatial resolution and enables rapid postprocessing. Thus we compared the accuracy of …

Strain and torsion quantification in mouse hearts under dobutamine stimulation using 2D multiphase MR DENSE

J Zhong, X Yu - Magnetic Resonance in Medicine, 2010 - Wiley Online Library
In this study, a 2D multiphase magnetic resonance displacement encoding with stimulated
echoes (DENSE) imaging and analysis method was developed for direct quantification of …

Emerging MRI methods in translational cardiovascular research

MH Vandsburger, FH Epstein - Journal of cardiovascular translational …, 2011 - Springer
Cardiac magnetic resonance imaging (CMR) has become a reference standard modality for
imaging of left ventricular (LV) structure and function and, using late gadolinium …

[HTML][HTML] Undersampled Cine 3D tagging for rapid assessment of cardiac motion

CT Stoeck, R Manka, P Boesiger, S Kozerke - Journal of Cardiovascular …, 2012 - Elsevier
Background CMR allows investigating cardiac contraction, rotation and torsion non-
invasively by the use of tagging sequences. Three-dimensional tagging has been proposed …

A comprehensive comparison between shortest-path HARP refinement, SinMod, and DENSEanalysis processing tools applied to CSPAMM and DENSE images

H Mella, J Mura, J Sotelo, S Uribe - Magnetic Resonance Imaging, 2021 - Elsevier
We addressed comprehensively the performance of Shortest-Path HARP Refinement (SP-
HR), SinMod, and DENSEanalysis using 2D slices of synthetic CSPAMM and DENSE …