Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams
ON Vassiliev, TA Wareing, J McGhee… - Physics in Medicine …, 2010 - iopscience.iop.org
A new grid-based Boltzmann equation solver, Acuros™, was developed specifically for
performing accurate and rapid radiotherapy dose calculations. In this study we …
performing accurate and rapid radiotherapy dose calculations. In this study we …
Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model‐based convolution methods in heterogeneous media
T Han, JK Mikell, M Salehpour, F Mourtada - Medical Physics, 2011 - Wiley Online Library
Purpose: The deterministic Acuros XB (AXB) algorithm was recently implemented in the
Eclipse treatment planning system. The goal of this study was to compare AXB performance …
Eclipse treatment planning system. The goal of this study was to compare AXB performance …
Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157
Dose calculation plays an important role in the accuracy of radiotherapy treatment planning
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …
Properties of unflattened photon beams shaped by a multileaf collimator
F Pönisch, U Titt, ON Vassiliev, SF Kry… - Medical …, 2006 - Wiley Online Library
Several studies have shown that removal of the flattening filter from the treatment head of a
clinical accelerator increases the dose rate and changes the lateral profile in radiation …
clinical accelerator increases the dose rate and changes the lateral profile in radiation …
Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: dose and IAEA‐compliant phase space calculations
M Constantin, J Perl, T LoSasso, A Salop… - Medical …, 2011 - Wiley Online Library
Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian
TrueBeam treatment head geometry imported from cad (computer aided design) without …
TrueBeam treatment head geometry imported from cad (computer aided design) without …
Monte Carlo computation of dosimetric amorphous silicon electronic portal images
This study develops and tests a method to compute dosimetric images for an amorphous
silicon flat‐panel detector so that an accurate quantitative comparison between measured …
silicon flat‐panel detector so that an accurate quantitative comparison between measured …
Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams
A Tzedakis, JE Damilakis, M Mazonakis… - Medical …, 2004 - Wiley Online Library
Our aim in the present study was to investigate the effects of initial electron beam
characteristics on Monte Carlo calculated absorbed dose distribution for a linac 6 MV photon …
characteristics on Monte Carlo calculated absorbed dose distribution for a linac 6 MV photon …
A Monte Carlo model for calculating out‐of‐field dose from a Varian beam
SF Kry, U Titt, F Pönisch, D Followill… - Medical …, 2006 - Wiley Online Library
Dose to the patient outside of the treatment field is important when evaluating the outcome of
radiotherapy treatments. However, determining out‐of‐field doses for any particular …
radiotherapy treatments. However, determining out‐of‐field doses for any particular …
Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation
There is a serious and growing concern about the increased risk of radiation-induced
second cancers and late tissue injuries associated with radiation treatment. To better …
second cancers and late tissue injuries associated with radiation treatment. To better …
Monte Carlo study of photon fields from a flattening filter‐free clinical accelerator
ON Vassiliev, U Titt, SF Kry, F Pönisch… - Medical …, 2006 - Wiley Online Library
In conventional clinical linear accelerators, the flattening filter scatters and absorbs a large
fraction of primary photons. Increasing the beam‐on time, which also increases the out‐of …
fraction of primary photons. Increasing the beam‐on time, which also increases the out‐of …