Detection methods and research progress of human serum albumin

JF Xu, YS Yang, AQ Jiang, HL Zhu - Critical Reviews in Analytical …, 2022 - Taylor & Francis
Human serum albumin (HSA) is a biological macromolecule with important physiological
functions; abnormal HSA levels are associated with coronary heart disease, multiple …

Methods of albumin estimation in clinical biochemistry: Past, present, and future

D Kumar, D Banerjee - Clinica Chimica Acta, 2017 - Elsevier
Estimation of serum and urinary albumin is routinely performed in clinical biochemistry
laboratories. In the past, precipitation-based methods were popular for estimation of human …

A rapid, simple measurement of human albumin in whole blood using a fluorescence immunoassay (I)

S Choi, EY Choi, DJ Kim, JH Kim, TS Kim, SW Oh - Clinica Chimica Acta, 2004 - Elsevier
Background: Human serum albumin (HSA) is the most abundant plasma protein and plays
key a role in metabolism. The variation in albumin concentration provides valuable …

Latex immunoagglutination assays

JA Molina‐Bolívar… - Journal of Macromolecular …, 2005 - Taylor & Francis
Latex immunoagglutination assays continue to be widely used in biology and medicine for
the detection of small quantities of an antibody or antigen of interest in fluid test samples …

Screen-printed carbon electrode-based electrochemical immunosensor for rapid detection of microalbuminuria

JZ Tsai, CJ Chen, K Settu, YF Lin, CL Chen… - Biosensors and …, 2016 - Elsevier
A urinary microalbumin test is used to detect early signs of kidney damage in people who
have a risk of chronic kidney disease, such as those with diabetes or hypertension. In this …

Using liquid crystals as a readout system in urinary albumin assays

VJ Aliño, KL Yang - Analyst, 2011 - pubs.rsc.org
Detecting human serum albumin (HSA) in urine samples is a standard procedure for the
diagnosis of kidney problems and the prognosis of patients with chronic kidney diseases …

A review of factors affecting the performances of latex agglutination tests

JL Ortega-Vinuesa… - Journal of Biomaterials …, 2001 - Taylor & Francis
The present review describes the different strategies followed to improve the performance of
latex agglutination tests. The analysis is mainly focused on the diverse parameters that affect …

Urine analysis in microfluidic devices

CC Lin, CC Tseng, TK Chuang, DS Lee, GB Lee - Analyst, 2011 - pubs.rsc.org
Microfluidics has attracted considerable attention since its early development in the 1980s
and has experienced rapid growth in the past three decades due to advantages associated …

Determination of adiponectin in serum using a latex particle-enhanced turbidimetric immunoassay with an automated analyzer

A Nishimura, T Sawai - Clinica Chimica Acta, 2006 - Elsevier
BACKGROUND: Adiponectin is an adipose-derived hormone that plays a role in regulating
metabolic processes such as fat partitioning and lipid and glucose metabolism …

Virus-enabled biosensor for human serum albumin

AF Ogata, JM Edgar, S Majumdar, JS Briggs… - Analytical …, 2017 - ACS Publications
The label-free detection of human serum albumin (HSA) in aqueous buffer is demonstrated
using a simple, monolithic, two-electrode electrochemical biosensor. In this device, both …