ICRU REPORT 96, dosimetry-guided radiopharmaceutical therapy

G Sgouros, WE Bolch, A Chiti… - Journal of the …, 2021 - journals.sagepub.com
The International Commission on Radiation Units and Measurements (ICRU), since its
inception in 1925, has had as its principal objective the development of internationally …

A free database of radionuclide voxel S values for the dosimetry of nonuniform activity distributions

N Lanconelli, M Pacilio, SL Meo, F Botta… - Physics in Medicine …, 2012 - iopscience.iop.org
The increasing availability of SPECT/CT devices with advanced technology offers the
opportunity for the accurate assessment of the radiation dose to the biological target volume …

Método de Monte Carlo: princípios e aplicações em Física Médica

H Yoriyaz - Revista Brasileira de Física Médica, 2009 - rbfm.org.br
O método de Monte Carlo tem se tornado, ao longo dos anos, uma ferramenta padrão para
cálculos de dose absorvida e outras grandezas de interesse nas áreas de terapêutica e …

Concepts and methods for the dosimetry of radioembolisation of the liver with Y-90-loaded microspheres

A Dieudonné, M Sanchez-Garcia… - Frontiers in Nuclear …, 2022 - frontiersin.org
This article aims at presenting in a didactic way, dosimetry concepts and methods that are
relevant for radio-embolization of the liver with 90Y-microspheres. The application of the …

An automated voxelized dosimetry tool for radionuclide therapy based on serial quantitative SPECT/CT imaging

PA Jackson, JM Beauregard, MS Hofman… - Medical …, 2013 - Wiley Online Library
Purpose: To create an accurate map of the distribution of radiation dose deposition in
healthy and target tissues during radionuclide therapy. Methods: Serial quantitative …

[HTML][HTML] A review of 3D image-based dosimetry, technical considerations and emerging perspectives in 90Y microsphere therapy

J O'Doherty - Journal of diagnostic imaging in therapy, 2015 - ncbi.nlm.nih.gov
Abstract Yttrium-90 radioembolization (90 Y-RE) is a well-established therapy for the
treatment of hepatocellular carcinoma (HCC) and also of metastatic liver deposits from other …

Development and validation of RAPID: a patient-specific Monte Carlo three-dimensional internal dosimetry platform

AE Besemer, YM Yang, JJ Grudzinski… - Cancer biotherapy & …, 2018 - liebertpub.com
This work describes the development and validation of a patient-specific Monte Carlo
internal dosimetry platform called RAPID (Radiopharmaceutical Assessment Platform for …

Comparison of internal dose estimates obtained using organ‐level, voxel S value, and Monte Carlo techniques

J Grimes, A Celler - Medical physics, 2014 - Wiley Online Library
Purpose: The authors' objective was to compare internal dose estimates obtained using the
Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the …

Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy

S Marcatili, C Pettinato, S Daniels… - Physics in Medicine …, 2013 - iopscience.iop.org
We developed and validated a Monte-Carlo-based application (RAYDOSE) to generate
patient-specific 3D dose maps on the basis of pre-treatment imaging studies. A CT DICOM …

Differences in 3D dose distributions due to calculation method of voxel S-values and the influence of image blurring in SPECT

M Pacilio, E Amato, N Lanconelli… - Physics in Medicine …, 2015 - iopscience.iop.org
This study compares 3D dose distributions obtained with voxel S values (VSVs) for soft
tissue, calculated by several methods at their current state-of-the-art, varying the degree of …