Characterization of fiber radiation dosimeters with different embedded scintillator materials for radiotherapy applications
Y Hu, Z Qin, Y Ma, W Zhao, W Sun, D Zhang… - Sensors and Actuators A …, 2018 - Elsevier
In-vivo real-time dose rate measurement has attracted much attention in the tumour-
treatment field because of the demand for precise delivery of radiotherapy. An optical fiber …
treatment field because of the demand for precise delivery of radiotherapy. An optical fiber …
Characterization of an inorganic scintillator for small‐field dosimetry in MR‐guided radiotherapy
D Cusumano, L Placidi, E D'Agostino… - Journal of applied …, 2020 - Wiley Online Library
Introduction Aim of this study is to dosimetrically characterize a new inorganic scintillator
designed for magnetic resonance‐guided radiotherapy (MRgRT) in the presence of 0.35 …
designed for magnetic resonance‐guided radiotherapy (MRgRT) in the presence of 0.35 …
Performance of a plastic scintillation fiber dosimeter based on different photoelectric devices
Y Yang, CP Yang, J Xin, HF Chen, ZX Xing… - Nuclear Science and …, 2021 - Springer
The photoelectric device of a scintillation dosimeter converts photons produced by radiation
into an electrical signal. Its features directly determine the overall performance of the …
into an electrical signal. Its features directly determine the overall performance of the …
[HTML][HTML] Flexible Optical Fiber Sensing: Materials, Methodologies, and Applications
J Gan, A Yang, Q Guo, Z Yang - Advanced Devices & …, 2024 - spj.science.org
Advances in stretchable and flexible sensors are meeting the demands of an expanding
range of applications, such as wearable healthcare, in vivo monitoring, and soft interactive …
range of applications, such as wearable healthcare, in vivo monitoring, and soft interactive …
Initial evaluation of the performance of novel inorganic scintillating detectors for small animal irradiation dosimetry
The purpose of this study was to design and evaluate the performance of four novel
inorganic scintillating detectors (ISDs) on the Small Animal Radiation Research Platform …
inorganic scintillating detectors (ISDs) on the Small Animal Radiation Research Platform …
[HTML][HTML] Low cost, high temporal resolution optical fiber-based γ-photon sensor for real-time pre-clinical evaluation of cancer-targeting radiopharmaceuticals
Cancer radiopharmaceutical therapies (RPTs) have demonstrated great promise in the
treatment of neuroendocrine and prostate cancer, giving hope to late-stage metastatic …
treatment of neuroendocrine and prostate cancer, giving hope to late-stage metastatic …
Real-time two dimensional dosimetry using Al2O3: C and Al2O3: C, Mg films
LF Nascimento, J Goossens, P Leblans… - Sensors and Actuators A …, 2021 - Elsevier
The Investigations of this article focus on the response of Al 2 O 3: C and Al 2 O 3: C, Mg
radioluminescence films for medical dosimetry in various MV photon beams. A dosimetry …
radioluminescence films for medical dosimetry in various MV photon beams. A dosimetry …
A competitive radioluminescence material-LiF: Mg, Cu, P for real-time dosimetry
S Zhang, K Tang, H Fan, L Fu - Radiation Measurements, 2022 - Elsevier
Currently, common radioluminescent (RL) materials have their own advantages and
disadvantages in real-time dosimetry. The most attractive RL materials are tissue equivalent …
disadvantages in real-time dosimetry. The most attractive RL materials are tissue equivalent …
Actual delivered dose calculation on intra-irradiation cone-beam computed tomography images: a phantom study
H Iramina, M Nakamura… - Physics in Medicine & …, 2021 - iopscience.iop.org
Cone-beam computed tomography (CBCT) images acquired during volumetric modulated
arc therapy (VMAT; ii-CBCT) can be used to calculate actual delivered doses (ADDs) …
arc therapy (VMAT; ii-CBCT) can be used to calculate actual delivered doses (ADDs) …
Two-dimensional real-time dosimetry system using micro-and nano-(C44H38P2) MnCl4 radioluminescence coatings
L de Freitas Nascimento, M De Saint-Hubert… - Radiation …, 2024 - Elsevier
This study investigates the impact of particle size on the radioluminescence (RL) response
of (C 44 H 38 P 2) MnCl 4 coatings, which have been made with five crystal size fractions …
of (C 44 H 38 P 2) MnCl 4 coatings, which have been made with five crystal size fractions …