[HTML][HTML] Sensitivity and specificity of color duplex ultrasound measurement in the estimation of internal carotid artery stenosis: a systematic review and meta-analysis

AS Jahromi, CS Cinà, Y Liu, CM Clase - Journal of vascular surgery, 2005 - Elsevier
BACKGROUND: Duplex ultrasound is widely used for the diagnosis of internal carotid artery
stenosis. Standard duplex ultrasound criteria for the grading of internal carotid artery …

Carotid sonography.

BA Carroll - Radiology, 1991 - pubs.rsna.org
S TROKE secondary to atherosclerotic disease is the third leading cause of death in the
United States. Three times as many stroke victims survive the catastrophic neunologic event …

Color Doppler imaging of the eye and orbit: technique and normal vascular anatomy

WE Lieb, SM Cohen, DA Merton… - Archives of …, 1991 - jamanetwork.com
• Color Doppler imaging is a recent advance in ultrasonography that allows simultaneous
two-dimensional imaging of structure and blood flow to be performed. Doppler information is …

CT angiography: application to the evaluation of carotid artery stenosis.

EH Dillon, MS Van Leeuwen, MA Fernandez… - Radiology, 1993 - pubs.rsna.org
PURPOSE: To determine whether computed tomographic (CT) angiography can be used to
accurately quantify carotid stenoses and differentiate severe stenoses from occlusions …

Accuracy and prognostic consequences of ultrasonography in identifying severe carotid artery stenosis

M Eliasziw, RN Rankin, AJ Fox, RB Haynes… - Stroke, 1995 - Am Heart Assoc
Background and Purpose The accuracy of routine ultrasonography in detecting severe
carotid artery stenosis was evaluated in comparison with cerebral angiography. The …

Detection and quantification of carotid artery stenosis: efficacy of various Doppler velocity parameters.

MG Hunink, JF Polak, MM Barlan… - AJR. American journal …, 1993 - Am Roentgen Ray Soc
The purpose of this study was to evaluate and compare the accuracies of the different
Doppler velocity parameters used to grade stenoses of the carotid artery. Seven velocity …

Quantification of atheromatous stenosis in the extracranial internal carotid artery

JM De Bray, B Glatt - Cerebrovascular diseases, 1995 - karger.com
An international consensus meeting to determine criteria for the quantification of stenosis of
the extracranial internal carotid artery was held in Paris on December 2 and 3, 1994. A …

Spiral CT angiography.

EH Dillon, MS Van Leeuwen… - … American journal of …, 1993 - Am Roentgen Ray Soc
Spiral CT angiography is a new, minimally invasive technique for vascular imaging that is
made possible by combining two recently developed techniques: slip-ring CT scanning and …

Color Doppler imaging of the ophthalmic artery blood flow spectra of patients who have had a transient ischemic attack: correlations with generalized iris …

LP Repo, MT Suhonen, ME Teräsvirta, KJ Koivisto - Ophthalmology, 1995 - Elsevier
Purpose: To study the interrelations among pseudoexfoliation syndrome (PXS), abnormal
iris transluminance, and ophthalmic artery blood flow in a controlled study. Methods …

Internal carotid arterial stenosis: CT angiography with volume rendering

X Leclerc, O Godefroy, C Lucas, JF Benhaim… - Radiology, 1999 - pubs.rsna.org
PURPOSE: To determine the reliability of helical computed tomography (CT) with volume
rendering for evaluation of internal carotid arterial stenosis. MATERIALS AND METHODS: In …