A force sensing automated insertion tool for cochlear electrode implantation

D Schurzig, RF Labadie, A Hussong… - … on Robotics and …, 2010 - ieeexplore.ieee.org
Cochlear electrode insertion is a challenging manual procedure. One technique requires the
physician to coordinate the motions of an electrode array approximately 1mm in diameter …

Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT)

C Güldner, S Wiegand, R Weiss, S Bien… - European Archives of …, 2012 - Springer
Until now more than 250,000 cochlea implantations have been performed worldwide. The
surgical procedure is well standardized. A discussion about the kind of postoperative …

The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens

T Kurzweg, CV Dalchow, M Bremke, O Majdani… - Ear and …, 2010 - journals.lww.com
Objectives: Radiological evaluation of the position of cochlear implant (CI) devices is an
upcoming method for quality control after CI surgery. First, results of imaging of the middle …

Pathology of the vestibulocochlear nerve

JD Swartz - Neuroimaging Clinics of North America, 2008 - Elsevier
Imaging of the vestibulocochlear nerve has evolved dramatically over the past few decades.
The imaging specialist now is involved in the diagnosis of far more diagnostic entities than …

Scalar localization of the electrode array after cochlear implantation: clinical experience using 64-slice multidetector computed tomography

JI Lane, RJ Witte, CLW Driscoll, JK Shallop… - Otology & …, 2007 - journals.lww.com
Objective: To use the improved resolution available with 64-slice multidetector computed
tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal …

Round window electrode insertion potentiates retention in the scala tympani

SEJ Connor, NJ Holland, A Agger, AC Leong… - Acta oto …, 2012 - Taylor & Francis
Conclusions: The round window membrane (RWM)-intentioned approach is superior to the
traditional bony cochleostomy (BC) approach in obtaining electrode placement within the …

Flat-panel CT for cochlear implant electrode imaging: comparison to multi-detector CT

TA Kennedy, N Connell, T Szczykutowicz… - Otology & …, 2016 - journals.lww.com
Background: The measurement of scalar location and intra-scalar position of cochlear
implantation (CI) electrodes using computed tomography (CT) is complicated by metallic …

Assessment of frequency-place mismatch by flat-panel CT and correlation with cochlear implant performance

D Zanetti, G Conte, F Di Berardino, FL Russo… - Otology & …, 2021 - journals.lww.com
Objective: To calculate the frequency allocation mismatch in a group of very selected
cochlear implant (CI) recipients and to contrast it with the speech perception performances …

Preimplant hearing threshold: an important predictor of hearing preservation in cochlear implantation with lateral wall electrodes

G Lee, S Lee, JH Chung, JW Choi - Otology & Neurotology, 2021 - journals.lww.com
Objective: To evaluate the outcomes and association factors of long-term hearing
preservation (HP) in cochlear implantation with lateral wall (LW) electrode arrays. Study …

Evaluation of cochlear implant electrode position after a modified round window insertion by means of a 64-multislice CT

I Todt, G Rademacher, J Wagner, F Göpel… - Acta oto …, 2009 - Taylor & Francis
Conclusion. The modified round window insertion enables reproducible insertion into the
scala tympani as demonstrated by comparing the 64-CT scanning data and the surgeon's …