Role of electrode placement as a contributor to variability in cochlear implant outcomes
CC Finley, TA Holden, LK Holden… - Otology & …, 2008 - journals.lww.com
Suboptimal cochlear implant (CI) electrode array placement may reduce presentation of
coded information to the central nervous system and, consequently, limit speech recognition …
coded information to the central nervous system and, consequently, limit speech recognition …
Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode …
E Boyer, A Karkas, A Attye, V Lefournier… - Otology & …, 2015 - journals.lww.com
Scalar Localization by Cone-Beam Computed Tomography of Coch... : Otology &
Neurotology Scalar Localization by Cone-Beam Computed Tomography of Cochlear …
Neurotology Scalar Localization by Cone-Beam Computed Tomography of Cochlear …
Accuracy of computed tomography detection of superior canal dehiscence
SM Sequeira, BR Whiting, JS Shimony… - Otology & …, 2011 - journals.lww.com
Background CT is an integral component of the diagnosis of SSCD. The prevalence of
dehiscence as measured on computed tomographic scan is approximately eightfold higher …
dehiscence as measured on computed tomographic scan is approximately eightfold higher …
Reliability of cone beam computed tomography in scalar localization of the electrode array: a radio histological study
Postoperative imaging plays a growing role in clinical studies concerning prognostic factors
in cochlear implantation. Indeed, intracochlear position of the cochlear implant has recently …
in cochlear implantation. Indeed, intracochlear position of the cochlear implant has recently …
Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis
J Teymouri, TE Hullar, TA Holden… - Otology & …, 2011 - journals.lww.com
Objective: To determine the efficacy of clinical computed tomographic (CT) imaging to verify
postoperative electrode array placement in cochlear implant (CI) patients. Study Design …
postoperative electrode array placement in cochlear implant (CI) patients. Study Design …
High-resolution secondary reconstructions with the use of flat panel CT in the clinical assessment of patients with cochlear implants
MS Pearl, A Roy, CJ Limb - American Journal of …, 2014 - Am Soc Neuroradiology
Radiologic assessment of cochlear implants can be limited because of metallic streak
artifacts and the high attenuation of the temporal bones. We report on 14 patients with 18 …
artifacts and the high attenuation of the temporal bones. We report on 14 patients with 18 …
Cochlear duct length–one size fits all?
Objective Recent studies demonstrated the utility of high-resolution computed tomography
(HRCT) scans in measuring basal cochlear length and cochlear insertion depths. These …
(HRCT) scans in measuring basal cochlear length and cochlear insertion depths. These …
Design of a tool integrating force sensing with automated insertion in cochlear implantation
D Schurzig, RF Labadie, A Hussong… - IEEE/ASME …, 2011 - ieeexplore.ieee.org
The quality of hearing restored to a deaf patient by a cochlear implant in hearing
preservation cochlear implant surgery (and possibly also in routine cochlear implant …
preservation cochlear implant surgery (and possibly also in routine cochlear implant …
[HTML][HTML] 3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study
SUMMARY A retrospective review of post-op cone beam CT (CBCT) of 8 adult patients and
14 fresh temporal bones that underwent cochlear implantation with straight flexible …
14 fresh temporal bones that underwent cochlear implantation with straight flexible …
64 MDCT in multiple trauma patients: imaging manifestations and clinical implications of active extravasation
SW Anderson, BC Lucey, JT Rhea, JA Soto - Emergency radiology, 2007 - Springer
The finding of active hemorrhage on computed tomography (CT) in trauma patients has
been shown to have significant clinical implications and has been incorporated into …
been shown to have significant clinical implications and has been incorporated into …