Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog1

FA Mettler Jr, W Huda, TT Yoshizumi, M Mahesh - Radiology, 2008 - pubs.rsna.org
Medical uses of radiation have grown very rapidly over the past decade, and, as of 2007,
medical uses represent the largest source of exposure to the US population. Most …

Occupational radiation doses to operators performing fluoroscopically-guided procedures

KP Kim, DL Miller, AB De Gonzalez, S Balter… - Health …, 2012 - journals.lww.com
In the past 30 y, the numbers and types of fluoroscopically-guided (FG) procedures have
increased dramatically. The objective of the present study is to provide estimated radiation …

ICRP publication 135: diagnostic reference levels in medical imaging

E Vañó, DL Miller, CJ Martin, MM Rehani… - Annals of the …, 2017 - journals.sagepub.com
The measurement of quantities related to patient dose for optimisation of protection in
medical imaging with ionising radiation began more than half a century ago. Beginning in …

[PDF][PDF] Guidelines for patient radiation dose management

MS Stecker, S Balter, RB Towbin, DL Miller… - Journal of Vascular …, 2009 - academia.edu
In the early 1990s, the US Food and Drug Administration (FDA) received reports of
significant radiation-induced skin injuries associated with interventional fluoroscopy (2) …

Radiation doses in interventional radiology procedures: the RAD-IR study part II: skin dose

DL Miller, S Balter, PE Cole, HT Lu, A Berenstein… - Journal of vascular and …, 2003 - Elsevier
PURPOSE: To determine peak skin dose (PSD), a measure of the likelihood of radiation-
induced skin effects, for a variety of common interventional radiology and interventional …

Radiological protection in fluoroscopically guided procedures performed outside the imaging department

MM Rehani, O Ciraj-Bjelac, E Vañó… - Annals of the …, 2010 - journals.sagepub.com
An increasing number of medical specialists are using fluoroscopy outside imaging
departments, but there has been general neglect of radiological protection coverage of …

Eye Lens Exposure to Radiation in Interventional Suites: Caution Is Warranted1

E Vano, L Gonzalez, JM Fernández, ZJ Haskal - Radiology, 2008 - pubs.rsna.org
Purpose: To report estimated radiation doses to the eye lens of the interventionalist from
procedures performed with and without use of radiation protection measures. Materials and …

Reference levels for patient radiation doses in interventional radiology: proposed initial values for US practice

DL Miller, D Kwon, GH Bonavia - Radiology, 2009 - pubs.rsna.org
Purpose To propose initial values for patient reference levels for fluoroscopically guided
procedures in the United States. Materials and Methods This secondary analysis of data …

[HTML][HTML] Editor's Choice–European Society for Vascular Surgery (ESVS) 2023 clinical practice guidelines on radiation safety

B Modarai, S Haulon, E Ainsbury, D Böckler… - European journal of …, 2023 - ejves.com
The majority of studies investigating the effectiveness of radiation shields focus on
procedures performed by cardiologists. These studies are, nevertheless, relevant also for …

Dose and image quality for a cone‐beam C‐arm CT system

R Fahrig, R Dixon, T Payne, RL Morin… - Medical …, 2006 - Wiley Online Library
We assess dose and image quality of a state‐of‐the‐art angiographic C‐arm system (Axiom
Artis dTA, Siemens Medical Solutions, Forchheim, Germany) for three‐dimensional neuro …