Soft cochlear implantation: rationale for the surgical approach

DR Friedland, C Runge-Samuelson - Trends in amplification, 2009 - journals.sagepub.com
Recent advances in cochlear implant technology have focused renewed attention on the
preservation of residual hearing. The focus on preservation of residual hearing is driven by …

Meta‐analysis of subjective complaints of vertigo and vestibular tests after cochlear implantation

T Hänsel, U Gauger, N Bernhard, N Behzadi… - The …, 2018 - Wiley Online Library
Objective Postoperative vertigo is a common complaint after cochlear implantation, but
published incidence rates differ vastly. The aim of the present study was to investigate both …

Potential insertion complications with cochlear implant electrodes

A Ishiyama, F Risi, P Boyd - Cochlear Implants International, 2020 - Taylor & Francis
Objectives: The aim of this discussion paper and literature review was to estimate the
incidence of a variety of complications associated with the surgical placement of cochlear …

The use of cone-beam computed tomography to determine cochlear implant electrode position in human temporal bones

SR Saeed, D Selvadurai, T Beale, N Biggs… - Otology & …, 2014 - journals.lww.com
Objective To assess the utility of cone-beam computed tomography (CBCT) imaging in the
estimation of cochlear implant (CI) electrode position in implanted temporal bones. Study …

Cone-beam CT versus multi-slice CT systems for postoperative imaging of cochlear implantation—a phantom study on image quality and radiation exposure using …

HJ Theunisse, RMS Joemai, TJJ Maal… - Otology & …, 2015 - journals.lww.com
Background CBCT has been described as a low-dose alternative with superior image
quality to MSCT for postoperative cochlear implant (CI) imaging, but to our knowledge, no …

In vivo measurements of the insertion depth of cochlear implant arrays using flat-panel volume computed tomography

A Trieger, A Schulze, M Schneider, T Zahnert… - Otology & …, 2011 - journals.lww.com
Objective: The development of a procedure for the measurement of insertion depth angles of
cochlear implant electrode arrays based on flat-panel computed tomography (FPCT) and the …

Influence of insertion depth in cochlear implantation on vertigo symptoms and vestibular function

J Louza, L Mertes, T Braun, R Gürkov… - American Journal of …, 2015 - Elsevier
Objectives The aim of the present study was to investigate the effect of the electrode
insertion depth in vestibular function after cochlear implantation. Material and methods In a …

Assessing the placement of a cochlear electrode array by multidimensional scaling

FJ Vanpoucke, PPB Boermans… - IEEE transactions on …, 2011 - ieeexplore.ieee.org
Correct placement of the electrode is crucial for cochlear implantation (CI) surgery. It
determines the access to the auditory nerve and subsequent hearing performance. Here, we …

[HTML][HTML] Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT)

C Güldner, S Wiegand, R Weiss, S Bien… - European Archives of …, 2012 - Springer
Until now more than 250,000 cochlea implantations have been performed worldwide. The
surgical procedure is well standardized. A discussion about the kind of postoperative …

The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens

T Kurzweg, CV Dalchow, M Bremke, O Majdani… - Ear and …, 2010 - journals.lww.com
Objectives: Radiological evaluation of the position of cochlear implant (CI) devices is an
upcoming method for quality control after CI surgery. First, results of imaging of the middle …