Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up

JE Sousa, MA Costa, AC Abizaid, BJ Rensing… - Circulation, 2001 - Am Heart Assoc
Background We have previously reported a virtual absence of neointimal hyperplasia 4
months after implantation of sirolimus-eluting stents. The aim of the present investigation …

Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up

JE Sousa, MA Costa, AC Abizaid, BJ Rensing… - …, 2001 - pubmed.ncbi.nlm.nih.gov
Background We have previously reported a virtual absence of neointimal hyperplasia 4
months after implantation of sirolimus-eluting stents. The aim of the present investigation …

[PDF][PDF] Sustained Suppression of Neointimal Proliferation by Sirolimus-Eluting Stents

JE Sousa, MA Costa, AC Abizaid, BJ Rensing… - 2001 - core.ac.uk
Background—We have previously reported a virtual absence of neointimal hyperplasia 4
months after implantation of sirolimus-eluting stents. The aim of the present investigation …

Sustained suppression of neointimal proliferation by sirolimus-eluting stents

JE Sousa, MA Costa, AC Abizaid, BJ Rensing… - …, 2001 - pesquisa.bvsalud.org
Background We have previously reported a virtual absence of neointimal hyperplasia 4
months after implantation of sirolimus-eluting stents. The aim of the present investigation …

Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up

E Sousa, G van Langenhove, A Sousa… - Circulation …, 2001 - repub.eur.nl
BACKGROUND: We have previously reported a virtual absence of neointimal hyperplasia 4
months after implantation of sirolimus-eluting stents. The aim of the present investigation …

[PDF][PDF] Sustained Suppression of Neointimal Proliferation by Sirolimus-Eluting Stents

JE Sousa, MA Costa, AC Abizaid, BJ Rensing… - 2001 - academia.edu
Background—We have previously reported a virtual absence of neointimal hyperplasia 4
months after implantation of sirolimus-eluting stents. The aim of the present investigation …

[引用][C] Sustained suppression of neointimal proliferation by sirolimus-eluting stents: One-year angiographic and intravascular ultrasound follow-up. Editorial

JE SOUSA, MA COSTA, J JAEGER… - … (New York, NY), 2001 - pascal-francis.inist.fr
Sustained suppression of neointimal proliferation by sirolimus-eluting stents: One-year
angiographic and intravascular ultrasound follow-up. Editorial CNRS Inist Pascal-Francis CNRS …

Sustained Suppression of Neointimal Proliferation by Sirolimus-Eluting Stents

JE Sousa, MA Costa, AC Abizaid, BJ Rensing… - Circulation, 2001 - cir.nii.ac.jp
抄録< jats: p>< jats: bold>< jats: italic>< jats: bold>< jats: italic> Background</jats:
italic></jats: bold></jats: italic></jats: bold> We have previously reported a virtual absence of …

Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up.

JE Sousa, MA Costa, AC Abizaid, BJ Rensing… - Circulation, 2001 - europepmc.org
Background We have previously reported a virtual absence of neointimal hyperplasia 4
months after implantation of sirolimus-eluting stents. The aim of the present investigation …

Sustained suppression of neointimal proliferation by sirolimus-eluting stents

JE Sousa, MA Costa, AC Abizaid, BJ Rensing… - …, 2001 - pesquisa.bvsalud.org
Background We have previously reported a virtual absence of neointimal hyperplasia 4
months after implantation of sirolimus-eluting stents. The aim of the present investigation …