Optimized 3D ultrashort echo time pulmonary MRI

KM Johnson, SB Fain, ML Schiebler… - Magnetic resonance in …, 2013 - Wiley Online Library
Purpose To optimize 3D radial ultrashort echo time MRI for high resolution whole‐lung
imaging. Methods 3D radial ultrashort echo time was implemented on a 3T scanner to …

Optimized 3D ultrashort echo time pulmonary MRI

KM Johnson, SB Fain… - Magnetic resonance …, 2013 - pubmed.ncbi.nlm.nih.gov
Purpose To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung
imaging. Methods 3D radial ultrashort echo time was implemented on a 3T scanner to …

Optimized 3D ultrashort echo time pulmonary MRI.

KM Johnson, SB Fain, ML Schiebler… - Magnetic Resonance in …, 2012 - europepmc.org
Methods 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the
effects of:(1) limited field-of-view excitation,(2) variable density readouts, and (3) radial …

Optimized 3D Ultrashort Echo Time Pulmonary MRI

KM Johnson, SB Fain, ML Schiebler… - Magnetic resonance in …, 2013 - iro.uiowa.edu
PurposeTo optimize 3D radial ultrashort echo time MRI for high resolution whole-lung
imaging. Methods3D radial ultrashort echo time was implemented on a 3T scanner to …

Optimized 3D ultrashort echo time pulmonary MRI

KM Johnson, SB Fain, ML Schiebler… - Magnetic Resonance in …, 2012 - cir.nii.ac.jp
抄録< jats: sec>< jats: title> Purpose</jats: title>< jats: p> To optimize 3D radial ultrashort
echo time MRI for high resolution whole‐lung imaging.</jats: p></jats: sec>< jats: sec>< jats …

Optimized 3D ultrashort echo time pulmonary MRI.

KM Johnson, SB Fain, ML Schiebler… - Magnetic Resonance …, 2013 - search.ebscohost.com
Purpose To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung
imaging. Methods 3D radial ultrashort echo time was implemented on a 3T scanner to …

Optimized 3D ultrashort echo time pulmonary MRI

KM Johnson, SB Fain, ML Schiebler… - Magnetic Resonance in …, 2013 - infona.pl
Purpose To optimize 3D radial ultrashort echo time MRI for high resolution whole‐lung
imaging. Methods 3D radial ultrashort echo time was implemented on a 3T scanner to …

[HTML][HTML] Optimized 3D Ultrashort Echo Time Pulmonary MRI

KM Johnson, SB Fain, ML Schiebler… - Magnetic resonance in …, 2013 - ncbi.nlm.nih.gov
Methods 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the
effects of:(1) limited field-of-view excitation,(2) variable density readouts, and (3) radial …

Optimized 3D ultrashort echo time pulmonary MRI.

KM Johnson, SB Fain, ML Schiebler… - Magnetic Resonance in …, 2012 - europepmc.org
Methods 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the
effects of:(1) limited field-of-view excitation,(2) variable density readouts, and (3) radial …