Study of the influence of radionuclide biokinetics on the efficiency of in vivo counting using Monte Carlo simulation

S Lamart, E Blanchardon, A Molokanov… - Health …, 2009 - journals.lww.com
To improve calibration methods of in vivo counting, our laboratory has developed a
computer tool to model internal contamination and assess in vivo activity and corresponding …

Automatic application of ICRP biokinetic models in voxel phantoms for in vivo counting and internal dose assessment

S Lamart, L De Carlan, E Blanchardon… - Radiation protection …, 2007 - academic.oup.com
As part of the improvement of calibration techniques of in vivo counting, the Laboratory of
Internal Dose Assessment of the Institute of Radiological Protection and Nuclear Safety has …

Efficiency correction factors of an ACCUSCAN whole-body counter due to the biodistribution of 134Cs, 137Cs and 60Co

J Bento, S Barros, P Teles, P Vaz… - Radiation protection …, 2013 - academic.oup.com
The efficiency calibration of whole-body counters (WBCs) for monitoring of internal
contaminations is usually performed with anthropomorphic physical phantoms assuming …

New method of voxel phantom creation: application for whole-body counting calibration and perspectives in individual internal dose assessment

L De Carlan, P Roch, E Blanchardon… - Radiation protection …, 2005 - academic.oup.com
The purpose of this work is to present an innovative approach for the creation and
application of voxel phantoms associated with the Monte Carlo calculation (MCNP) for the …

Application of voxel phantoms in whole-body counting for the validation of calibration phantoms and the assessment of uncertainties

L Carlan, P Roch, E Blanchardon… - Radiation protection …, 2007 - academic.oup.com
This article is dedicated to the application of voxel phantoms in whole-body counting
calibration. The first study was performed to validate this approach using IGOR, a physical …

[PDF][PDF] Numerical efficiency calibration of in vivo measurement systems

L Hegenbart - 2009 - core.ac.uk
Detector efficiency calibration of in vivo bioassay measurements is based on physical
anthropomorphic phantoms that can be loaded with radionuclides of the suspected …

Monte Carlo calculation of whole body counter efficiency factors for different computational phantoms

CVG Ferreira, JS Piedade, MRD Prado… - Applied Radiation and …, 2023 - Elsevier
Individual monitoring can provide an estimate of the radioactivity present in the body of the
exposed individuals. Periodic monitoring of occupationally exposed individuals is of great …

Monte Carlo simulations of the whole-body counter at Spiez Laboratory Switzerland: Impact of phantom size and biokinetic model

L Desorgher, N Mosimann, R Althaus, C Wirz… - Radiation …, 2022 - Elsevier
Whole-body counters (WBC) are used to detect potential intake of radioisotopes in the
human body. To achieve a precise measurement of an incorporated activity, a WBC needs …

Application of Monte Carlo calculation for the virtual calibration of a low-energy in vivo counting system

N Pierrat, L de Carlan, D Cavadore… - IEEE transactions on …, 2005 - ieeexplore.ieee.org
Internal dose assessment can be derived from the measurement of retained activity in the
whole body or in an organ at a given time. In radiation protection, this assessment, so-called …

Monte Carlo simulation of the movement and detection efficiency of a whole-body counting system using a BOMAB phantom

J Bento, S Barros, P Teles, M Neves… - Radiation protection …, 2012 - academic.oup.com
This study reports on the computational analysis and experimental calibration of the whole-
body counting detection equipment at the Nuclear and Technological Institute (ITN) in …