Reassessing glenoid inclination in reverse total shoulder arthroplasty with glenosphere lateralization

KA Mahendraraj, MV Shields… - The Bone & Joint …, 2021 - boneandjoint.org.uk
Aims Existing literature indicates that inferiorly inclined glenoid baseplates following reverse
total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined …

Posteroinferior Glenosphere Positioning is Associated with Improved Range of Motion Following Reverse Shoulder Arthroplasty with a 135° Inlay Humeral …

T Pak, J Ardebol, AI Kilic, BW Sears… - Journal of Shoulder and …, 2024 - Elsevier
Background Optimal glenosphere positioning in a lateralized reverse shoulder arthroplasty
(RSA) to maximize functional outcomes has yet to be clearly defined. Center of rotation …

Assessing glenosphere position: superior approach versus deltopectoral for reverse shoulder arthroplasty

WR Aibinder, NJ Clark, BS Schoch… - Journal of shoulder and …, 2018 - Elsevier
Background The anterosuperior (AS) approach for reverse total shoulder arthroplasty
(RTSA) has been reported as a risk factor for baseplate malposition because of potential …

Baseplate retroversion does not affect postoperative outcomes after reverse shoulder arthroplasty

R Elmallah, D Swanson, K Le, J Kirsch… - Journal of Shoulder and …, 2022 - Elsevier
Background There is concern that excessive glenoid component retroversion leads to
altered biomechanics and baseplate failure in reverse shoulder arthroplasty (RSA) …

Does glenohumeral offset affect clinical outcomes in a lateralized reverse total shoulder arthroplasty?

GJ Wolf, JJ Reid, JR Rabinowitz, DA Barcel… - Journal of Shoulder and …, 2023 - Elsevier
Background Reverse total shoulder arthroplasty (rTSA) exhibits high rates of success and
low complication rates. rTSA has undergone numerous design adaptations over recent …

[HTML][HTML] Does isolated glenosphere lateralization affect outcomes in reverse shoulder arthroplasty?

JJ King, KM Hones, TW Wright, C Roche… - … & Traumatology: Surgery …, 2023 - Elsevier
Introduction While lateralization of the glenohumeral center of rotation during reverse
shoulder arthroplasty (RSA) has benefits of maintaining tension on the remaining rotator cuff …

Mid-term comparative study between the glenoid and humerus lateralization designs for reverse total shoulder arthroplasty: which lateralization design is better?

HH Lee, SE Park, JH Ji, HS Jun - BMC Musculoskeletal Disorders, 2023 - Springer
Introduction The complications of the conventional medialized design for reverse total
shoulder arthroplasty (RSA) are increased scapular notching, and decreased external …

Lateralising reverse shoulder arthroplasty using bony increased offset (BIO-RSA) or increasing glenoid component diameter: comparison of clinical, radiographic and …

AA Macken, GA Buijze, M Kimmeyer, T Hees… - Journal of Orthopaedics …, 2024 - Springer
Background This study aims to compare the range of motion (ROM) of reverse shoulder
arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) …

[PDF][PDF] Comparison of clinical and radiological results according to glenosphere position in reverse total shoulder arthroplasty: a short-term follow-up study

CH Choi, SG Kim, JJ Lee… - Clinics in orthopedic …, 2017 - synapse.koreamed.org
Background In a previous biomechanical study, eccentric glenospheres with more inferior
position of the center of rotation were shown to improve range of motion and reduce the …

Clinical and radiological outcomes in lateralized versus nonlateralized and distalized glenospheres in reverse total shoulder arthroplasty: a randomized control trial

BR Southam, YH Bedeir, BM Johnson… - Journal of Shoulder and …, 2023 - Elsevier
Background Lateralization in reverse total shoulder arthroplasty (RTSA) has been used to
theoretically offer the potential benefits of reduced scapular notching rates and improved …