[HTML][HTML] CdZnTe semiconductor-based dual imager combining collimatorless and Compton imaging: Monte Carlo simulation

Y Kim, W Lee - Nuclear Engineering and Technology, 2024 - Elsevier
Compton imaging excels at visualizing gamma rays in the range of several hundred
kiloelectronvolts to several megaelectronvolts. However, this technique has limitations in the …

Improvement of Compton imaging efficiency by using side-neighbor events

W Wang, WR Kaye, JC Kim, F Zhang, Z He - Nuclear Instruments and …, 2012 - Elsevier
In a pixelated detector, an electron cloud can be collected by and shared between several
adjacent pixels. By including these charge-sharing events, the Compton-imaging efficiency …

Simulation study of the backward-scattering effect in Compton imager

G Xiaofeng, X Qingpei, T Dongfeng, W Yi… - Applied Radiation and …, 2017 - Elsevier
In the field of nuclear medicine, nuclear security and astrophysics, Compton imaging is a
promising technique for gamma-ray source imaging. We are developing a Compton imager …

Artifacts in high-energy Compton imaging with 3-D position-sensitive CdZnTe

D Shy, J Xia, Z He - IEEE Transactions on Nuclear Science, 2020 - ieeexplore.ieee.org
High-energy gamma-ray imaging is an important technique with applications in homeland
security and medical imaging. Recent advancements in the cadmium zinc telluride (CdZnTe) …

Characterization and applications of a CdZnTe-based gamma-ray imager

ML Galloway - Ph. D. Thesis, 2014 - ui.adsabs.harvard.edu
Detection of electromagnetic radiation in the form of gamma rays provides a means to
discover the presence of nuclear sources and the occurrence of highly-energetic events that …

4-pi Compton imaging using a single three-dimensional position sensitive cadmium zinc telluride detector

CE Lehner - 2004 - search.proquest.com
Compton imagers are promising tools for nuclear non-proliferation, astronomy, and medical
applications, but typically have a limited angular field-of-view and poor efficiency resulting …

Experimental demonstration of coded aperture imaging using thick 3D-position-sensitive CdZnTe detectors

SJ Kaye, WR Kaye, Z He - 2009 IEEE Nuclear Science …, 2009 - ieeexplore.ieee.org
3D-position-sensitive CdZnTe semiconductor detectors have demonstrated 4¿ Compton
imaging capability and excellent energy resolution at room-temperature operation. However …

Source motion compensated coded aperture imaging using thick 3D-position-sensitive CdZnTe detectors

SJ Kaye, JM Jaworski, WR Kaye… - 2011 IEEE Nuclear …, 2011 - ieeexplore.ieee.org
The 18-detector array system consists of eighteen 20mm× 20mm× 15mm CdZnTe detectors.
In addition to spectroscopic capabilities, it has the ability to image gamma-ray sources with …

Gamma-ray imaging and polarization measurement using three-dimensional position-sensitive cadmium zinc telluride detectors

D Xu - Ph. D. Thesis, 2006 - ui.adsabs.harvard.edu
The three-dimensional position-sensitive CdZnTe detector is a novel room temperature
semiconductor gamma-ray spectrometer. It was initially developed to achieve good energy …

Super-MeV Compton Imaging and 3D Gamma-Ray Imaging Using Pixelated CdZnTe

D Shy - 2020 - deepblue.lib.umich.edu
The dissertation presents work in gamma-ray imaging in the MeV range, 3D Compton
imaging, and time encoded imaging. The first thrust in high energy gamma-ray imaging …