[HTML][HTML] Sutureless versus conventional bioprostheses for aortic valve replacement in severe symptomatic aortic valve stenosis

T Fischlein, T Folliguet, B Meuris, ML Shrestha… - The Journal of Thoracic …, 2021 - Elsevier
Objective Sutureless aortic valves are a novel option for aortic valve replacement. We
sought to demonstrate noninferiority of sutureless versus standard bioprostheses in severe …

Better short-term outcome by using sutureless valves: a propensity-matched score analysis

F Pollari, G Santarpino, AM Dell'Aquila… - The Annals of Thoracic …, 2014 - Elsevier
Background Sutureless aortic valve prostheses have the potential of shortening ischemic
time. However, whether shorter operative times may also result in improved patient …

Sutureless aortic valve replacement: first-year single-center experience

G Santarpino, S Pfeiffer, J Schmidt, G Concistrè… - The Annals of thoracic …, 2012 - Elsevier
BACKGROUND: Sutureless aortic bioprostheses bear the potential of easy implantation,
reduced ischemic time, and surgical trauma in aortic valve replacement. We herein show our …

New sutureless aortic valve prosthesis: another tool in less invasive aortic valve replacement

K Zannis, T Folliguet, F Laborde - Current opinion in cardiology, 2012 - journals.lww.com
New sutureless aortic valve prosthesis: another tool in less... : Current Opinion in
Cardiology New sutureless aortic valve prosthesis: another tool in less invasive aortic valve …

Sutureless versus stented bioprostheses for aortic valve replacement: the randomized PERSIST-AVR study design

R Lorusso, T Folliguet, M Shrestha… - The Thoracic and …, 2020 - thieme-connect.com
Introduction Sutureless biological valves for surgical aortic valve replacement (SAVR),
characterized by the absence of anchoring sutures at the aortic annulus, are gaining …

[HTML][HTML] The sutureless aortic valve at 1 year: a large multicenter cohort study

T Fischlein, B Meuris, K Hakim-Meibodi… - The Journal of thoracic …, 2016 - Elsevier
Objective Sutureless aortic valve replacement (AVR) offers an alternative to standard AVR in
aortic stenosis. This prospective, single-arm study aimed to demonstrate safety and …

[HTML][HTML] Early single-center experience in sutureless aortic valve implantation in 120 patients

HC Eichstaedt, J Easo, T Härle, OE Dapunt - The Journal of Thoracic and …, 2014 - Elsevier
Objective The study objective was to evaluate the safety and efficacy of sutureless self-
expanding nitinol stent-frame aortic valve prostheses made of equine pericardium implanted …

[HTML][HTML] A comparison of conventional surgery, transcatheter aortic valve replacement, and sutureless valves in “real-world” patients with aortic stenosis and …

C Muneretto, O Alfieri, BM Cesana, G Bisleri… - The Journal of Thoracic …, 2015 - Elsevier
Objective We sought to investigate the clinical outcomes of patients with isolated severe
aortic stenosis and an intermediate-to high-risk profile treated by means of conventional …

[HTML][HTML] Surgical aortic valve replacement with new-generation bioprostheses: Sutureless versus rapid-deployment

A D'Onofrio, S Salizzoni, C Filippini, C Tessari… - The Journal of Thoracic …, 2020 - Elsevier
Objectives The aim of this retrospective multicenter study was to compare early clinical and
hemodynamic outcomes of Perceval-S sutureless (Livanova, London, United Kingdom) and …

[HTML][HTML] Clinical performance of a sutureless aortic bioprosthesis: five-year results of the 3f Enable long-term follow-up study

L Englberger, TP Carrel, M Doss, J Sadowski… - The Journal of thoracic …, 2014 - Elsevier
Objective Sutureless valves are designed to facilitate surgical implantation, including less-
invasive techniques in aortic valve replacement, by maintaining surgical precision of …