[HTML][HTML] Antitachycardia pacing programming in implantable cardioverter defibrillator: a systematic review

E De Maria, D Giacopelli, A Borghi… - World journal of …, 2017 - ncbi.nlm.nih.gov
Implantable cardioverter defibrillator (ICD) programming involves several parameters. In
recent years antitachycardia pacing (ATP) has gained an increasing importance in the …

[HTML][HTML] Antitachycardia pacing success in implantable cardioverter-defibrillators by patient, device, and programming characteristics

LD Sterns, A Auricchio, EJ Schloss, D Lexcen… - Heart Rhythm, 2023 - Elsevier
Background Antitachycardia pacing (ATP) is an established implantable cardioverter-
defibrillator (ICD) therapy that terminates ventricular tachycardias (VTs) without painful ICD …

Programming antitachycardia pacing for primary prevention in patients with implantable cardioverter defibrillators: results from the PROVE trial

M Saeed, CG Neason, M Razavi… - Journal of …, 2010 - Wiley Online Library
Programming ATP for ICD Patients. Objectives: The PROVE trial was designed to determine
if antitachycardia pacing (ATP) is clinically beneficial for primary prevention in patients who …

Additional antitachycardia pacing programming strategies further reduce unnecessary implantable cardioverter-defibrillator shocks

B Joung, DR Lexcen, CK Ching, MT Silver, JP Piccini… - Heart Rhythm, 2020 - Elsevier
Background Antitachycardia pacing (ATP) is routinely used to terminate ventricular
tachyarrhythmias (VTs). However, little guidance exists on the most effective programming of …

A randomized study to compare ramp versus burst antitachycardia pacing therapies to treat fast ventricular tachyarrhythmias in patients with implantable cardioverter …

MM Gulizia, L Piraino, M Scherillo… - Circulation …, 2009 - Am Heart Assoc
Background—In patients with implantable cardioverter-defibrillators (ICDs), antitachycardia
pacing (ATP) is highly effective in terminating fast ventricular tachycardias (FVTs) and lowers …

Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study

RP Martins, H Blangy, L Muresan, L Freysz… - Europace, 2012 - academic.oup.com
Aims Little is known about the optimal number of antitachycardia pacing (ATP) attempts to
programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long …

Antitachycardia pacing in patients with implantable cardioverter defibrillators: how many attempts are useful?

R Fries, A Heisel, G Kalweit, J Jung… - Pacing and clinical …, 1997 - Wiley Online Library
The purpose of this study was to determine the termination and acceleration rates for 1 to 6
attempts of antitachycardia pacing (ATP) delivered by ICD in order to terminate …

[HTML][HTML] Reassessing the role of antitachycardia pacing in fast ventricular arrhythmias in primary prevention implantable cardioverter-defibrillator recipients: results …

C Schuger, JP Daubert, W Zareba, S Rosero, P Yong… - Heart Rhythm, 2021 - Elsevier
Background In Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate
Therapy (MADIT-RIT), high-rate cutoff (arm B) and delayed therapy (arm C) reduced the risk …

A trial design for evaluation of empiric programming of implantable cardioverter defibrillators to improve patient management

JM Morgan, LD Sterns, JL Hanson… - Current Controlled Trials …, 2004 - Springer
The delivery of implantable cardioverter defibrillator (ICD) therapy is sophisticated and
requires the programming of over 100 settings. Physicians tailor these settings with the …

Initial clinical experience with a new automated antitachycardia pacing algorithm: feasibility and safety in an ambulatory patient cohort

R Yee, JD Fisher, U Birgersdotter-Green… - Circulation …, 2017 - Am Heart Assoc
Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD)
decreases patient shock burden but has recognized limitations. A new automated ATP …