MRI‐based myelin water imaging: a technical review

E Alonso‐Ortiz, IR Levesque… - Magnetic resonance in …, 2015 - Wiley Online Library
Multiexponential T2 relaxation time measurement in the central nervous system shows a
component that originates from water trapped between the lipid bilayers of myelin. This …

Myelin water imaging: implementation and development at 3.0 T and comparison to 1.5 T measurements

SH Kolind, B Mädler, S Fischer, DKB Li… - … in Medicine: An …, 2009 - Wiley Online Library
Multicomponent T2 relaxation imaging can be used to measure signal from water trapped
between myelin bilayers; the ratio of myelin water signal to total water is termed the myelin …

Rapid whole cerebrum myelin water imaging using a 3D GRASE sequence

T Prasloski, A Rauscher, AL MacKay, M Hodgson… - Neuroimage, 2012 - Elsevier
Myelin water imaging, a magnetic resonance imaging technique capable of resolving the
fraction of water molecules which are located between the layers of myelin, is a valuable tool …

Magnetic resonance of myelin water: an in vivo marker for myelin

AL MacKay, C Laule - Brain plasticity, 2016 - content.iospress.com
Myelin is critical for healthy brain function. An accurate in vivo measure of myelin content
has important implications for understanding brain plasticity and neurodegenerative …

So you want to image myelin using MRI: an overview and practical guide for myelin water imaging

J Lee, JW Hyun, J Lee, EJ Choi… - Journal of Magnetic …, 2021 - Wiley Online Library
Myelin water imaging (MWI) is an MRI imaging biomarker for myelin. This method can
generate an in vivo whole‐brain myelin water fraction map in approximately 10 minutes. It …

In vivo multi-slice mapping of myelin water content using T2* decay

D Hwang, DH Kim, YP Du - Neuroimage, 2010 - Elsevier
Quantitative assessment of the myelin water content in the brain can substantially improve
our understanding of white matter diseases such as multiple sclerosis. In this study, in vivo …

Comparison of myelin water fraction from multiecho T2 decay curve and steady‐state methods

J Zhang, SH Kolind, C Laule… - Magnetic resonance in …, 2015 - Wiley Online Library
Purpose Myelin water fraction is conventionally measured from the T2 decay curve.
Recently, a steady‐state approach entitled multicomponent‐driven equilibrium single pulse …

Myelin water imaging depends on white matter fiber orientation in the human brain

C Birkl, J Doucette, M Fan… - Magnetic resonance …, 2021 - Wiley Online Library
Purpose The multi‐exponential T2 decay of the MRI signal from cerebral white matter can be
separated into short T2 components related to myelin water and long T2 components related …

Myelin water imaging of multiple sclerosis at 7 T: correlations with histopathology

C Laule, P Kozlowski, E Leung, DKB Li, AL MacKay… - Neuroimage, 2008 - Elsevier
Myelin water imaging (MWI) promises to be invaluable in understanding neurological
diseases like MS. However, a limitation of MWI is signal to noise ratio. Recently, a number of …

Myelin water imaging to detect demyelination and remyelination and its validation in pathology

C Laule, GRW Moore - Brain Pathology, 2018 - Wiley Online Library
Damage to myelin is a key feature of multiple sclerosis (MS) pathology. Magnetic resonance
imaging (MRI) has revolutionized our ability to detect and monitor MS pathology in vivo …