A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology

K Erlandsson, I Buvat, PH Pretorius… - Physics in Medicine …, 2012 - iopscience.iop.org
Accurate quantification in PET and SPECT requires correction for a number of physical
factors, such as photon attenuation, Compton scattering and random coincidences (in PET) …

Positron emission tomography partial volume correction: estimation and algorithms

JAD Aston, VJ Cunningham… - Journal of Cerebral …, 2002 - journals.sagepub.com
Partial volume effects in positron emission tomography (PET) lead to quantitative under-and
over-estimations of the regional concentrations of radioactivity in reconstructed images and …

A multiresolution image based approach for correction of partial volume effects in emission tomography

N Boussion, M Hatt, F Lamare, Y Bizais… - Physics in Medicine …, 2006 - iopscience.iop.org
Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission
tomography. They lead to a loss of signal in tissues of size similar to the point spread …

[PDF][PDF] Correction for partial volume effects in PET: principle and validation

OG Rousset, Y Ma, AC Evans - Journal of nuclear medicine, 1998 - Soc Nuclear Med
Correction for Partial Volume Effects in PET: Principle and Validation Page 1 Correction for
Partial Volume Effects in PET: Principle and Validation Olivier G. Roussel, Yilong Ma and Alan …

PETPVC: a toolbox for performing partial volume correction techniques in positron emission tomography

BA Thomas, V Cuplov, A Bousse… - Physics in Medicine …, 2016 - iopscience.iop.org
Positron emission tomography (PET) images are degraded by a phenomenon known as the
partial volume effect (PVE). Approaches have been developed to reduce PVEs, typically …

PET quantification: strategies for partial volume correction

V Bettinardi, I Castiglioni, E De Bernardi… - Clinical and Translational …, 2014 - Springer
Despite the continuous evolution of positron emission tomography (PET) technology, the
spatial resolution (SR) of PET images remains poor (4–6 mm) compared with that of …

Partial volume effect compensation for quantitative brain SPECT imaging

Y Du, BMW Tsui, EC Frey - IEEE transactions on medical …, 2005 - ieeexplore.ieee.org
Partial volume (PV) effects degrade the quantitative accuracy of SPECT brain images. In this
paper, we extended a PV compensation (PVC) method originally developed for brain PET …

Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging

N Boussion, C Cheze Le Rest, M Hatt… - European journal of …, 2009 - Springer
Abstract Purpose Partial volume effects (PVEs) are consequences of the limited resolution of
emission tomography. The aim of the present study was to compare two new voxel-wise …

Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on local topology

AS Kirov, JZ Piao, CR Schmidtlein - Physics in Medicine & …, 2008 - iopscience.iop.org
Correcting positron emission tomography (PET) images for the partial volume effect (PVE)
due to the limited resolution of PET has been a long-standing challenge. Various …

Correction of partial-volume effect for PET striatal imaging: fast implementation and study of robustness

V Frouin, C Comtat, A Reilhac… - Journal of Nuclear …, 2002 - Soc Nuclear Med
PET imaging of D2 receptors or 18F-l-dopa metabolism are reference protocols to follow and
study neurodegenerative diseases, but the accuracy of striatal PET imaging is limited by the …