Tissue oximeter with selectable measurement depth using spatially resolved near-infrared spectroscopy
M Niwayama, N Unno - Sensors, 2021 - mdpi.com
Tissue oxygenation sensing at a few millimeters deep is useful for surgical and
postoperative management. However, the measurement sensitivity at each depth and the …
postoperative management. However, the measurement sensitivity at each depth and the …
Influence of overlying tissue and probe geometry on the sensitivity of a near-infrared tissue oximeter
W Feng, D Haishu, T Fenghua, Z Jun… - Physiological …, 2001 - iopscience.iop.org
In this paper, the influences of overlying tissue and detecting distance between the source
and the detector on the measurement of a tissue oximeter were discussed. The signal-noise …
and the detector on the measurement of a tissue oximeter were discussed. The signal-noise …
[HTML][HTML] Non-invasive measurement and validation of tissue oxygen saturation covered with overlying tissues
Y Teng, H Ding, L Huang, Y Li, Q Shan, D Ye… - Progress in Natural …, 2008 - Elsevier
In this paper, the biological tissue oxygen saturation (rSO2) is obtained non-invasively and
in real time based on near infrared spectroscopy (NIRS) using two emitting wavelengths and …
in real time based on near infrared spectroscopy (NIRS) using two emitting wavelengths and …
[引用][C] Development of a portable tissue oximeter using near infra-red spectroscopy
T Shiga, K Tanabe, Y Nakase, T Shida… - Medical and Biological …, 1995 - Springer
1Omron Institute of Life Science Co. Ltd., Ukyo-ku, Kyoto 615, Japan 2Department of
Veterinary Radiology, School of Veterinary Medicine, Azabu University, Japan aDepartment …
Veterinary Radiology, School of Veterinary Medicine, Azabu University, Japan aDepartment …
Study of an algorithm based on model experiments and diffusion theory for a portable tissue oximeter
T Shiga, K Yamamoto, K Tanabe… - … of biomedical optics, 1997 - spiedigitallibrary.org
A portable tissue oximeter that uses light-emitting diodes and two-wavelength near infrared
spectroscopy has been developed. The tissue oximeter is compact enough to be portable …
spectroscopy has been developed. The tissue oximeter is compact enough to be portable …
Noncontact measurement of deep tissue absorption coefficient using Spatially Resolved Near‐Infrared Spectroscopy
M Niwayama, H Murata, S Sone… - IEEJ Transactions on …, 2007 - Wiley Online Library
We examined the influence of probe‐tissue distance on the relationship between the deep
tissue absorption coefficient and the spatial profile of light intensity by Monte Carlo …
tissue absorption coefficient and the spatial profile of light intensity by Monte Carlo …
Robustness of tissue oxygenation estimates by continuous wave space-resolved near infrared spectroscopy
Significance Continuous wave near infrared spectroscopy (CW-NIRS) is widely exploited in
clinics to estimate skeletal muscles and brain cortex oxygenation. Spatially resolved …
clinics to estimate skeletal muscles and brain cortex oxygenation. Spatially resolved …
Validation of NIRS in measuring tissue hemoglobin concentration and oxygen saturation on ex vivo and isolated limb models
X Xu, W Zhu, V Padival, M Xia, X Cheng… - … of Tissue V, 2003 - spiedigitallibrary.org
Photonify's tissue spectrometer uses Near-Infrared Spectroscopy for real-time, noninvasive
measurement of hemoglobin concentration and oxygen saturation [SO 2] of biological …
measurement of hemoglobin concentration and oxygen saturation [SO 2] of biological …
Near-infrared muscle oximeter that can correct the influence of a subcutaneous fat layer
K Yamamoto, M Niwayama, L Lin… - … : New Tool in …, 1998 - spiedigitallibrary.org
The inhomogeneity of tissue structure greatly affects the sensitivity of tissue oxygenation
measurement by reflectance NIRS. We have proposed a method for correcting the influence …
measurement by reflectance NIRS. We have proposed a method for correcting the influence …
Noninvasive monitoring of deep tissue oxygenation in buried flaps by time-resolved near-infrared spectroscopy in pigs
R Lartizien, A Planat-Chrétien, M Berger… - Plastic and …, 2020 - journals.lww.com
Background: Flap monitoring in reconstructive surgery is particularly important because flap
failure is a dramatic event for the patient and for the medical team. Noninvasive deep tissue …
failure is a dramatic event for the patient and for the medical team. Noninvasive deep tissue …