[HTML][HTML] Analysis of the US Food and Drug Administration Manufacturer and User Facility Device Experience database for adverse events involving Amplatzer septal …

DJ DiBardino, DB McElhinney, AK Kaza… - The Journal of thoracic …, 2009 - Elsevier
OBJECTIVE: Amplatzer (AGA Medical Corporation, Plymouth, Minn) septal and vascular
occluder devices have significantly altered the care of patients with congenital heart …

Major complications associated with transcatheter atrial septal occluder implantation: a review of the medical literature and the manufacturer and user facility device …

JW Delaney, JS Li, JF Rhodes - Congenital heart disease, 2007 - Wiley Online Library
Objective. To summarize major complications and outcome for patients receiving
percutaneous closure of atrial septal communications. Design. The Medline database and …

Community use of the amplatzer atrial septal defect occluder: results of the multicenter MAGIC atrial septal defect study

AD Everett, J Jennings, E Sibinga, C Owada, DS Lim… - Pediatric …, 2009 - Springer
The objective of this study was to determine the initial safety and results of unrestricted multi-
institution routine community use of the Amplatzer Septal Occluder (ASO) for atrial septal …

Atrioventricular block after transcatheter ASD closure using the Amplatzer septal occluder: risk factors and recommendations

SJ Al‐Anani, H Weber, ZM Hijazi - Catheterization and …, 2010 - Wiley Online Library
Atrial septal defects (ASD) are among the most common forms of congenital heart disease
accounting for 10% of all defects. Until now, surgical closure was considered the sole …

Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize …

Z Amin, ZM Hijazi, JL Bass… - Catheterization and …, 2004 - Wiley Online Library
The objectives of this study were to identify possible risk factors that may lead to erosion of
the Amplatzer septal occluder (ASO) and recommend ways to minimize future risk. There …

Comparison of results and complications of surgical and Amplatzer device closure of atrial septal defects

F Berger, M Vogel, V Alexi-Meskishvili… - The Journal of thoracic …, 1999 - Elsevier
Objectives: Results and complications of surgical versus transcatheter treatment of atrial
septal defect in the current era are compared. Methods: All consecutive patients with a …

Echocardiologists' role in the deployment of the Amplatzer atrial septal occluder device in adults

JC Cooke, JS Gelman, RW Harper - Journal of the American Society of …, 2001 - Elsevier
Use of the Amplatzer Septal Occluder device to close selected secundum atrial septal
defects is ever-increasing. This article illustrates the central role of the echocardiologist …

Comparison of atrial septal defect closure using Amplatzer septal occluder with surgery

K Durongpisitkul, J Soongswang, D Laohaprasitiporn… - Pediatric …, 2002 - Springer
Our study reports the results of a comparison of closure of atrial septal defect (ASD)
surgically with transcatheter closure using the Amplatzer septal occluder. Patients having an …

Closure of secundum atrial septal defects with the AMPLATZER septal occluder: a prospective, multicenter, post-approval study

DR Turner, CY Owada, CJ Sang Jr… - Circulation …, 2017 - Am Heart Assoc
Background—Prospective data on the medium-term safety and effectiveness of the
AMPLATZER Septal Occluder in clinical practice are not available. The objective of this …

Reversible atrioventricular block associated with closure of atrial septal defects using the Amplatzer device

K Suda, MJ Raboisson, E Piette, NS Dahdah… - Journal of the American …, 2004 - jacc.org
Objectives: We sought to determine the incidence, nature, and predisposing factors of
atrioventricular block (AVB) associated with closure of atrial septal defects (ASDs) using the …