Very high rate programming in primary prevention patients with reduced ejection fraction implanted with a defibrillator: Results from a large multicenter controlled …

N Clementy, F Challal, E Marijon, S Boveda, P Defaye… - Heart Rhythm, 2017 - Elsevier
Background Programming implantable cardioverter-defibrillators (ICDs) with a high-rate
therapy strategy has proven to be effective in reducing shocks and is associated with a …

Long-term follow-up on high-rate cut-off programming for implantable cardioverter defibrillators in primary prevention patients with left ventricular systolic dysfunction

N Clementy, B Pierre, B Lallemand, O Marie… - Europace, 2012 - academic.oup.com
Abstract Aims Implantable cardioverter defibrillators (ICDs) are efficient in reducing mortality
in patients with left ventricular systolic dysfunction. High-rate cut-off programming may be …

[HTML][HTML] Reduction in inappropriate therapy and mortality through ICD programming

AJ Moss, C Schuger, CA Beck, MW Brown… - … England Journal of …, 2012 - Mass Medical Soc
Background The implantable cardioverter–defibrillator (ICD) is highly effective in reducing
mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are …

ICD programming to reduce shocks and improve outcomes

V Kutyifa, W Zareba, AJ Moss - Current cardiology reports, 2014 - Springer
Despite the clinical benefit of implantable cardioverter defibrillator (ICD), there is a high
frequency of inappropriate ICD therapy associated with impaired quality of life, unwanted …

Impact of programming strategies aimed at reducing nonessential implantable cardioverter defibrillator therapies on mortality: a systematic review and meta-analysis

VH Tan, SB Wilton, V Kuriachan… - Circulation …, 2014 - Am Heart Assoc
Background—Patients who receive implantable cardioverter defibrillator therapies are at
higher risk of death versus those who do not. Programmed settings to reduce nonessential …

Programming implantable cardioverter-defibrillator therapy zones to high ranges to prevent delivery of inappropriate device therapies in patients with primary …

S Cay, U Canpolat, F Ucar, O Ozeke, F Ozcan… - The American Journal of …, 2015 - Elsevier
Inappropriate shock is a frequently seen clinical problem despite advanced technologies
used in modern implantable cardioverter-defibrillator (ICD) devices. Our aim was to …

Programming implantable cardioverter–defibrillator in primary prevention: Guideline concordance and outcomes

T Ananwattanasuk, T Tanawuttiwat… - Heart Rhythm, 2020 - Elsevier
Background Inappropriate therapy is a common adverse effect in patients with an
implantable cardioverter–defibrillator (ICD) that may be prevented by appropriate …

Programming of implantable cardioverter defibrillators for primary prevention: outcomes at centers with high vs. low concordance with guidelines

P Teerawongsakul, T Ananwattanasuk… - Journal of Interventional …, 2023 - Springer
Background While ICD therapy reduction programming strategies are recommended in
current multi-society guidelines, concerns remain about a possible trade-off between the …

Mortality reduction in relation to implantable cardioverter defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate …

AC Ruwald, C Schuger, AJ Moss, V Kutyifa… - Circulation …, 2014 - Am Heart Assoc
Background—The benefit of novel implantable cardioverter defibrillator (ICD) programming
in reducing inappropriate ICD therapy and mortality was demonstrated in Multicenter …

Feedback to providers improves evidence-based implantable cardioverter-defibrillator programming and reduces shocks

MT Silver, LD Sterns, JP Piccini, B Joung, CK Ching… - Heart Rhythm, 2015 - Elsevier
Background Implantable cardioverter-defibrillator (ICD) shocks are associated with
increased anxiety, health care utilization, and potentially mortality. Objective The purpose of …