Near-field high-resolution coded aperture gamma-ray imaging with separable masks

S Sun, Y Liu, X Ouyang - Nuclear Instruments and Methods in Physics …, 2020 - Elsevier
A coded aperture gamma camera based on a novel imaging model which decomposes the
mask projections as a superposition of two separable functions was proposed for near-field …

Reconstruction method for gamma-ray coded-aperture imaging based on mask and anti-mask functions

D Fan, R Wu, D Wei, Y Li, T Tan, G Zha - Radiation Measurements, 2024 - Elsevier
Gamma-ray coded-aperture imaging technology plays an important role in nuclear security,
decommissioning of nuclear facilities, and nuclear medicine diagnosis. However, under …

Design of a near-field coded aperture cameras for high-resolution medical and industrial gamma-ray imaging

R Accorsi - 2001 - dspace.mit.edu
Coded Aperture Imaging is a technique originally developed for X-ray astronomy, where
typical imaging problems are characterized by far-field geometry and an object made of …

Impact of aperture-thickness on the real-time imaging characteristics of coded-aperture gamma cameras

S Park, J Boo, M Hammig, M Jeong - Nuclear Engineering and Technology, 2021 - Elsevier
The mask parameters of a coded aperture are critical design features when optimizing the
performance of a gamma-ray camera. In this paper, experiments and Monte Carlo …

Development of coded-aperture imaging with a compact gamma camera

M Gmar, O Gal, C Le Goaller, OP Ivanov… - … on Nuclear Science, 2004 - ieeexplore.ieee.org
In the 1990s, CEA has developed a very compact operational gamma camera, CARTOGAM,
capable of mapping the surrounding radioactivity and representing it superimposed onto a …

Impact of mask thickness on the imaging performance of the coded-aperture gamma camera

B Zhu, Z Wang, Z Zheng, R Zhou… - Journal of …, 2022 - iopscience.iop.org
Coded-aperture gamma imaging techniques have been applied widely in several radiation
monitoring fields. However, in terms of the design of the coded-aperture mask, the category …

Development of coded-aperture imaging with a compact gamma camera

M Gmar, O Gal, C Le Goaller, OP Ivanov… - 2003 IEEE Nuclear …, 2003 - ieeexplore.ieee.org
In the 1990's, CEA has developed one of the most compact operational gamma cameras in
the world, CARTOGAM, capable of mapping the surrounding radioactivity and representing …

A dual-modality volumetric gamma-ray imager for near-field applications

E Frame, R Barnowski, D Gunter… - … on Nuclear Science, 2022 - ieeexplore.ieee.org
There is an ever-growing need for instrumentation that provides both high-resolution and
sensitive volumetric gamma-ray imaging capabilities across a wide range of photon …

[PDF][PDF] Near field three-dimensional coded aperture techniques: theoretical and experimental exploration for applications in imaging and detection systems

L Zhang - 1998 - dspace.mit.edu
Coded aperture techniques based on a cyclic difference set uniformly redundant array
(URA) increase the sensitivity of an imaging system without degrading the spatial resolution …

High energy 3-D nuclear medicine imaging using coded apertures with a conventional gamma camera

L Zhang, RC Lanza, BKP Horn… - 1998 IEEE Nuclear …, 1998 - ieeexplore.ieee.org
Standard nuclear medicine imaging uses photon collimation and thus suffers from very low
sensitivity, especially if high energy (> 511 keV) isotopes are to be imaged. Coded aperture …