Photon activation therapy: a Monte Carlo study on dose enhancement by various sources and activation media
M Bakhshabadi, M Ghorbani, AS Meigooni - Australasian physical & …, 2013 - Springer
In the present study, a number of brachytherapy sources and activation media were
simulated using MCNPX code and the results were analyzed based on the dose …
simulated using MCNPX code and the results were analyzed based on the dose …
Effect of tissue composition on dose distribution in brachytherapy with various photon emitting sources
M Ghorbani, F Salahshour, A Haghparast… - Journal of …, 2014 - termedia.pl
Purpose: The aim of this study is to compare the dose in various soft tissues in
brachytherapy with photon emitting sources. Material and methods: 103 Pd, 125 I, 169 Yb …
brachytherapy with photon emitting sources. Material and methods: 103 Pd, 125 I, 169 Yb …
brachytherapy k‐edge dose enhancement with
LA Young, IJ Kalet, JS Rasey, JA Nelson - Medical Physics, 1998 - Wiley Online Library
Photon activation is a radiotherapy technique in which an element is added to the absorbing
medium to raise the probability that a photoelectric interaction will occur, thus causing an …
medium to raise the probability that a photoelectric interaction will occur, thus causing an …
A systematic evaluation of the dose-rate constant determined by photon spectrometry for 21 different models of low-energy photon-emitting brachytherapy sources
ZJ Chen, R Nath - Physics in Medicine & Biology, 2010 - iopscience.iop.org
The aim of this study was to perform a systematic comparison of the dose-rate constant (Λ)
determined by the photon spectrometry technique (PST) with the consensus value (CON Λ) …
determined by the photon spectrometry technique (PST) with the consensus value (CON Λ) …
Dosimetric characterization of the high‐dose‐rate brachytherapy source using the AAPM and ESTRO formalism
MTH Thanh, JJ Munro III… - Journal of Applied Clinical …, 2015 - Wiley Online Library
The Source Production & Equipment Co.(SPEC) model is a new brachytherapy source
model intended for use as a temporary high‐dose‐rate (HDR) brachytherapy source for the …
model intended for use as a temporary high‐dose‐rate (HDR) brachytherapy source for the …
[HTML][HTML] Energy modulated photon radiotherapy: a Monte Carlo feasibility study
A novel treatment modality termed energy modulated photon radiotherapy (EMXRT) was
investigated. The first step of EMXRT was to determine beam energy for each gantry …
investigated. The first step of EMXRT was to determine beam energy for each gantry …
Preliminary Monte Carlo simulation of non-laser light sources for photodynamic therapy
MS Alva-Sánchez, A Quevedo, A Bonatto… - Journal of Physics …, 2021 - iopscience.iop.org
In photodynamic therapy (PDT), a photosensitizing agent is administered following
irradiation on the target volume. The wavelength beam to activate the photosensitizer is …
irradiation on the target volume. The wavelength beam to activate the photosensitizer is …
Photon energy‐modulated radiotherapy: Monte Carlo simulation and treatment planning study
Purpose: To demonstrate the feasibility of photon energy‐modulated radiotherapy during
beam‐on time. Methods: A cylindrical device made of aluminum was conceptually proposed …
beam‐on time. Methods: A cylindrical device made of aluminum was conceptually proposed …
Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium
Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-
43U1 protocol where all media are considered to be water. Several dose calculation …
43U1 protocol where all media are considered to be water. Several dose calculation …
Photonuclear production in tissue for different 50 MV bremsstrahlung beams
A Sätherberg, L Johansson - Medical Physics, 1998 - Wiley Online Library
Calculations of photonuclear production in “tissue approximation” and the relative heavy
particle dose to photon dose at dose maximum in water have been performed. Different 50 …
particle dose to photon dose at dose maximum in water have been performed. Different 50 …