Photon activation therapy: a Monte Carlo study on dose enhancement by various sources and activation media

M Bakhshabadi, M Ghorbani, AS Meigooni - Australasian physical & …, 2013 - Springer
In the present study, a number of brachytherapy sources and activation media were
simulated using MCNPX code and the results were analyzed based on the dose …

Effect of tissue composition on dose distribution in brachytherapy with various photon emitting sources

M Ghorbani, F Salahshour, A Haghparast… - Journal of …, 2014 - termedia.pl
Purpose: The aim of this study is to compare the dose in various soft tissues in
brachytherapy with photon emitting sources. Material and methods: 103 Pd, 125 I, 169 Yb …

brachytherapy k‐edge dose enhancement with

LA Young, IJ Kalet, JS Rasey, JA Nelson - Medical Physics, 1998 - Wiley Online Library
Photon activation is a radiotherapy technique in which an element is added to the absorbing
medium to raise the probability that a photoelectric interaction will occur, thus causing an …

A systematic evaluation of the dose-rate constant determined by photon spectrometry for 21 different models of low-energy photon-emitting brachytherapy sources

ZJ Chen, R Nath - Physics in Medicine & Biology, 2010 - iopscience.iop.org
The aim of this study was to perform a systematic comparison of the dose-rate constant (Λ)
determined by the photon spectrometry technique (PST) with the consensus value (CON Λ) …

Dosimetric characterization of the high‐dose‐rate brachytherapy source using the AAPM and ESTRO formalism

MTH Thanh, JJ Munro III… - Journal of Applied Clinical …, 2015 - Wiley Online Library
The Source Production & Equipment Co.(SPEC) model is a new brachytherapy source
model intended for use as a temporary high‐dose‐rate (HDR) brachytherapy source for the …

[HTML][HTML] Energy modulated photon radiotherapy: a Monte Carlo feasibility study

Y Zhang, Y Feng, X Ming, J Deng - BioMed Research International, 2016 - hindawi.com
A novel treatment modality termed energy modulated photon radiotherapy (EMXRT) was
investigated. The first step of EMXRT was to determine beam energy for each gantry …

Preliminary Monte Carlo simulation of non-laser light sources for photodynamic therapy

MS Alva-Sánchez, A Quevedo, A Bonatto… - Journal of Physics …, 2021 - iopscience.iop.org
In photodynamic therapy (PDT), a photosensitizing agent is administered following
irradiation on the target volume. The wavelength beam to activate the photosensitizer is …

Photon energy‐modulated radiotherapy: Monte Carlo simulation and treatment planning study

JM Park, J Kim, C Heon Choi, EK Chie, IH Kim… - Medical …, 2012 - Wiley Online Library
Purpose: To demonstrate the feasibility of photon energy‐modulated radiotherapy during
beam‐on time. Methods: A cylindrical device made of aluminum was conceptually proposed …

Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

GP Fonseca, ÅC Tedgren, B Reniers… - Physics in Medicine …, 2015 - iopscience.iop.org
Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-
43U1 protocol where all media are considered to be water. Several dose calculation …

Photonuclear production in tissue for different 50 MV bremsstrahlung beams

A Sätherberg, L Johansson - Medical Physics, 1998 - Wiley Online Library
Calculations of photonuclear production in “tissue approximation” and the relative heavy