Extraction of His Bundle Pacing Lead: More Difficult than Coronary Sinus Lead Extraction: An Analysis of 3897 Lead Extraction Procedures Including 27 His and 253 …

P Stefańczyk, W Jacheć, A Kutarski, P Dąbrowski… - Biomedicines, 2024 - mdpi.com
Background: Experience with the transvenous extraction of leads used for His bundle pacing
(HBP) is limited. Methods: Analysis of 3897 extractions including 27 HBP and 253 LVP (left …

Extraction of the permanent His bundle pacing lead: Safety outcomes and feasibility of reimplantation

P Vijayaraman, FA Subzposh, A Naperkowski - Heart rhythm, 2019 - Elsevier
Background Permanent His bundle pacing (HBP) is a physiological alternative to right
ventricular pacing. However, concerns remain about the feasibility and safety of lead …

Extraction of a very old His bundle pacing lead: A safe and effective procedure?

F Migliore, P Dall'Aglio, PV Falzone… - Pacing and Clinical …, 2021 - Wiley Online Library
Permanent His bundle pacing (HBP) has rapidly been adapted into clinical practice in recent
years as a physiologic pacing. The 3830 (Medtronic Inc, MN, USA) pacing lead commonly …

[PDF][PDF] Experience with transvenous lead extraction of His bundle pacing leads

K Boczar, A Sławuta, A Ciesielski… - Polish Heart …, 2024 - journals.viamedica.pl
Background: Nowadays, we observe a growing interest in conduction system pacing (CSP).
Therefore, we expect the number of patients with CSP to increase significantly in the coming …

Coronary sinus lead extraction in the era of cardiac resynchronization therapy: single center experience

B Kasravi, S Tobias, MJ Barnes… - Pacing and clinical …, 2005 - Wiley Online Library
As the number of coronary sinus (CS) lead implantations for cardiac resynchronization
therapy increases so will the need for extraction of these leads. The safety of extraction of …

Percutaneous lead and system extraction in patients with cardiac resynchronization therapy (CRT) devices and coronary sinus leads

SE Williams, A Arujuna, J Whitaker… - Pacing and clinical …, 2011 - Wiley Online Library
Background: Cardiac resynchronization therapy (CRT) device and coronary sinus (CS) lead
extraction is required due to the occurrence of system infection, malfunction, or upgrade …

Transvenous extraction of His bundle pacing lead: New challenge in the field of lead extraction

K Boczar, A Ząbek, M Dębski, J Gajek… - Cardiology …, 2019 - journals.viamedica.pl
Figure 1. A. Initial ICD-DR system consisted of defibrillator lead Medtronic Sprint 6935M62
(RV) and Medtronic 3830-74cm lumenless lead designed for His bundle pacing (His) …

Clinical predictors of incomplete coronary sinus lead removal during transvenous lead extraction in patients with cardiac resynchronization therapy

K Hayashi, A Younis, T Callahan, B Baranowski… - Heart Rhythm, 2023 - Elsevier
Background Reports of coronary sinus (CS) lead removal include small studies with short
implant durations. Procedural outcomes for mature CS leads removed with long duration …

Initial experience with transvenous lead extraction of His bundle pacing leads

K Boczar, A Ząbek… - Polish Heart …, 2023 - journals.viamedica.pl
Methods A prospective analysis of the records included all patients with HBP leads who
underwent TLE from October 201 1 to February 202 3. The patient inclusion criteria were the …

Results of transvenous lead extraction of coronary sinus leads in patients with cardiac resynchronization therapy

CT Starck, E Caliskan, H Klein, J Steffel… - Chinese Medical …, 2013 - journals.lww.com
Background The need for transvenous lead extraction procedures of coronary sinus (CS)