Recording clinical interactions and wiretapping laws

K Brook, FGA de Meneses, SA Quraishi - Anesthesia & Analgesia, 2023 - journals.lww.com
REFERENCES 1. Greiwe G, Balfanz V, Hapfelmeier A, et al. Pulse wave analysis using the
pressure recording analytical method to measure cardiac output in pediatric cardiac surgery …

Tracking changes in cardiac output: statistical considerations on the 4-quadrant plot and the polar plot methodology

B Saugel, O Grothe, JY Wagner - Anesthesia & Analgesia, 2015 - journals.lww.com
When comparing 2 technologies for measuring hemodynamic parameters with regard to
their ability to track changes, 2 graphical tools are omnipresent in the literature: the 4 …

Pulse wave analysis to estimate cardiac output: comment

S Hughey, J Cole, G Booth - Anesthesiology, 2021 - pubs.asahq.org
Anesthesiology,“Pulse Wave Analysis to Estimate Cardiac Output.” 1 As military
anesthesiologists, we are very excited about the future potential to allow advanced …

Cardiac output measurements in young children: Reply

TS Sigurdsson - Anesthesiology, 2020 - pubs.asahq.org
Sigurdsson et al. conducted and reported a superb investigation examining measurement of
cardiac output in small children by extracorporeal arteriovenous ultrasonography with …

Predicting fluid responsiveness in children: are the studied indicators of value in the setting of loss and replacement?

PA Stricker, JE Fiadjoe, DR Jobes - British journal of …, 2011 - academic.oup.com
1 Paarmann H, Groesdonk HV, Sedemund-Adib B, et al. Lack of agreement between
pulmonary arterial thermodilution cardiac output and the pressure recording analytical …

Pulse contour analysis for cardiac output monitoring in cardiac surgery for congenital heart disease

A Mahajan, A Shabanie, J Turner… - Anesthesia & …, 2003 - journals.lww.com
IMPLICATIONS: Our results suggest that the pulse contour analysis cardiac output (CO)
monitoring in patients undergoing congenital heart surgery may not provide as accurate or …

You (still) can't disprove the existence of dragons

PE Scuderi - The Journal of the American Society of …, 2005 - pubs.asahq.org
HYPOTENSION during spinal anesthesia for cesarean delivery has been of concern since
the 1960s. 1 Along with multiple strategies aimed at treating or preventing hypotension …

Reply to Faraoni D, Fenger-Eriksen C, Gillard S et al. Evaluation of dynamic parameters of thrombus formation measured on whole blood using rotational …

O Grottke, H Cate - Pediatric Anesthesia, 2015 - search.ebscohost.com
A letter to the editor is presented in response to the article" Evaluation of dynamic
parameters of thrombus formation measured on whole blood using rotational …

New standards of monitoring guidelines: a reply.

G Rodney, T Meek, AA Klein, AF Nimmo - Anaesthesia, 2021 - search.ebscohost.com
Abstract We thank Dr Wong et al. for their useful comments [1] regarding the recently
published standards of monitoring [2] and welcome their summary of the nuances of …

Data Interpretation in Anesthesia: A Clinical Guide

EW Richter, R Sniecinski - Anesthesia & Analgesia, 2018 - journals.lww.com
At first glance, one could be forgiven for assuming that a book titled Data Interpretation in
Anesthesia: A Clinical Guide was a practical statistics primer for anesthesiologists. In reality …