Sources of indoor and outdoor PM2. 5 concentrations in primary schools

F Amato, I Rivas, M Viana, T Moreno, L Bouso… - Science of the Total …, 2014 - Elsevier
Children spend a third of their day in the classroom, where air pollution levels may differ
substantially from those outdoors due to specific indoor sources. Air pollution exposure …

[HTML][HTML] Child exposure to indoor and outdoor air pollutants in schools in Barcelona, Spain

I Rivas, M Viana, T Moreno, M Pandolfi, F Amato… - Environment …, 2014 - Elsevier
Proximity to road traffic involves higher health risks because of atmospheric pollutants. In
addition to outdoor air, indoor air quality contributes to overall exposure. In the framework of …

Elemental characterization and source identification of size resolved atmospheric particles in French classrooms

DT Tran, LY Alleman, P Coddeville, JC Galloo - Atmospheric Environment, 2012 - Elsevier
Indoor airborne particles were chemically characterized to identify their major sources in 3
elementary schools presenting different site typologies (rural, urban, and industrial) in the …

Indoor and outdoor particulate matter concentrations at schools in the Athens area

E Diapouli, A Chaloulakou… - Indoor and Built …, 2007 - journals.sagepub.com
Simultaneous indoor and outdoor PM10 and PM2. 5 concentration measurements were
conducted in seven primary schools in the Athens area during the winter of 2003-04 and …

Particulate matter in the indoor air of classrooms—exploratory results from Munich and surrounding area

H Fromme, D Twardella, S Dietrich, D Heitmann… - Atmospheric …, 2007 - Elsevier
Numerous epidemiological studies have demonstrated the association between particle
mass (PM) concentration in outside air and the occurrence of health related problems and/or …

[HTML][HTML] The relationship between indoor and outdoor levels of PM10 and its chemical composition at schools in a coastal region in Spain

S Pallarés, ET Gómez, A Martínez, MM Jordán - Heliyon, 2019 - cell.com
PM10 levels and its chemical composition were studied inside and outdoor of seven primary
schools (3 in urban environment, 3 in industrial environment, 1 in rural environment) located …

Characterization of indoor air quality in primary schools in Antwerp, Belgium.

M Stranger, SS Potgieter-Vermaak… - Indoor air, 2008 - search.ebscohost.com
The indoor air quality of 27 primary schools located in the city centre and suburbs of
Antwerp, Belgium, was assessed. The primary aim was to obtain correlations between the …

[HTML][HTML] Airborne particulate matter in school classrooms of northern Italy

S Rovelli, A Cattaneo, CP Nuzzi, A Spinazzè… - International journal of …, 2014 - mdpi.com
Indoor size-fractioned particulate matter (PM) was measured in seven schools in Milan, to
characterize their concentration levels in classrooms, compare the measured concentrations …

Children's exposure and dose assessment to particulate matter in Lisbon

T Faria, V Martins, C Correia, N Canha… - Building and …, 2020 - Elsevier
Abstract Exposure to Particulate Matter (PM) has been associated with adverse health
effects. The main objective of this study is to quantify children's exposure to PM and the …

[HTML][HTML] Classroom indoor PM2. 5 sources and exposures in inner-city schools

A Carrion-Matta, CM Kang, JM Gaffin… - Environment …, 2019 - Elsevier
Children spend over 6 ha day in schools and have higher asthma morbidity from school
environmental exposures. The present study aims to determine indoor and outdoor possible …