Damage to inner ear structure during cochlear implantation: Correlation between insertion force and radio-histological findings in temporal bone specimens
Cochlear implant insertion should be as least traumatic as possible in order to reduce
trauma to the cochlear sensory structures. The force applied to the cochlea during array …
trauma to the cochlear sensory structures. The force applied to the cochlea during array …
Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array
M Mirsalehi, TS Rau, L Harbach, S Hügl… - European Archives of …, 2017 - Springer
The aim of the study was to evaluate insertion forces during manual insertion of a straight
atraumatic electrode in human temporal bones, and post-implantation histologic evaluation …
atraumatic electrode in human temporal bones, and post-implantation histologic evaluation …
Anatomic considerations of cochlear morphology and its implications for insertion trauma in cochlear implant surgery
BM Verbist, L Ferrarini, JJ Briaire, A Zarowski… - Otology & …, 2009 - journals.lww.com
Background: Insertion trauma in cochlear implant surgery is a feared surgical risk, potentially
causing neural degeneration and altered performance of the implant. In literature, insertion …
causing neural degeneration and altered performance of the implant. In literature, insertion …
Cochlear implant insertion forces in microdissected human cochlea to evaluate a prototype array
Cochlear implant array insertion forces are potentially related to cochlear trauma. We
compared these forces between a standard (Digisonic SP; Neurelec, Vallauris, France) and …
compared these forces between a standard (Digisonic SP; Neurelec, Vallauris, France) and …
Impact of electrode insertion depth on intracochlear trauma
O Adunka, J Kiefer - Otolaryngology—head and neck surgery, 2006 - journals.sagepub.com
Objective To assess the effect of cochlear implant (CI) insertion depth and surgical
technique on intracochlear trauma. Study Design and Setting Twenty one fresh human …
technique on intracochlear trauma. Study Design and Setting Twenty one fresh human …
A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion technique
JT Roland Jr - The Laryngoscope, 2005 - Wiley Online Library
Abstract Objectives and Hypothesis: This study has the specific aim of evaluating the
insertion characteristics of a new cochlear implant electrode. Techniques for evaluation of …
insertion characteristics of a new cochlear implant electrode. Techniques for evaluation of …
A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. I: Comparison of Nucleus banded and Nucleus Contour™ …
P Wardrop, D Whinney, SJ Rebscher, JT Roland Jr… - Hearing research, 2005 - Elsevier
In recent years, new designs of cochlear implant electrodes have been introduced in an
attempt to improve efficiency and performance by locating stimulation sites closer to spiral …
attempt to improve efficiency and performance by locating stimulation sites closer to spiral …
Three-dimensional force profile during cochlear implantation depends on individual geometry and insertion trauma
Objectives: To preserve the acoustic hearing, cochlear implantation has to be as atraumatic
as possible. Therefore, understanding the impact of the cochlear geometry on insertion …
as possible. Therefore, understanding the impact of the cochlear geometry on insertion …
Systematic review: Radiological and histological evidence of cochlear implant insertion trauma in adult patients
E Hoskison, S Mitchell, C Coulson - Cochlear implants international, 2017 - Taylor & Francis
Introduction: Cochlear implantation (CI) has developed from its origins in the 1980s. Initially,
CI was for profound bilateral hearing impairment. However, candidacy for CI have become …
CI was for profound bilateral hearing impairment. However, candidacy for CI have become …
Insertional trauma of multichannel cochlear implants
DB Welling, R Hinojosa, BJ Gantz, JT Lee - The Laryngoscope, 1993 - Wiley Online Library
Insertional trauma to the cochlea from three different multichannel cochlear implant
electrodes was evaluated in a single‐blind controlled study in fresh human temporal bones …
electrodes was evaluated in a single‐blind controlled study in fresh human temporal bones …
相关搜索
- implant electrodes insertion trauma
- ear structure insertion force
- ear structure cochlear implantation
- insertion force cochlear implantation
- bone specimens insertion forces
- ear structure bone specimens
- intracochlear trauma insertion forces
- electrode array insertion forces
- bone specimens cochlear implantation
- insertion trauma cochlear morphology
- bone specimens intracochlear trauma
- bone specimens electrode array
- cochlear morphology implant surgery
- individual geometry cochlear implantation
- insertion trauma cochlear implantation
- force profile cochlear implantation