Determination of sodium and potassium with ion-selective electrodes.
N Fogh-Andersen, PD Wimberley, J Thode… - Clinical …, 1984 - academic.oup.com
We compared different sample-handling techniques for measurement of Na+ and K+ with
ion-selective electrodes (ISE). Imprecision was less for venous blood (with a minimum of …
ion-selective electrodes (ISE). Imprecision was less for venous blood (with a minimum of …
Ion-selective electrodes for sodium and potassium: a new problem of what is measured and what should be reported.
AH Maas, O Siggaard-Andersen, HF Weisberg… - Clinical …, 1985 - academic.oup.com
For clinical purposes the activities of Na+ and K+ obtained with ion-selective electrodes in
undiluted whole blood or serum should be multiplied by an appropriate factor to obtain the …
undiluted whole blood or serum should be multiplied by an appropriate factor to obtain the …
[PDF][PDF] Normal range for serum sodium by ion-selective electrode analysis exceeds that by flame photometry.
W Annan, NA Kirwan, WS Robertson - Clinical chemistry, 1979 - Citeseer
American Hospital Supply (UK) Ltd., Didcot, Oxon. An instrument supplied for a trial period in
our laboratory produced results for plasma and serum so-dium that differed significantly from …
our laboratory produced results for plasma and serum so-dium that differed significantly from …
Ion-selective electrode determination of sodium and potassium in blood and urine
SAH Khalil, GJ Moody, JDR Thomas - Analytical Letters, 1986 - Taylor & Francis
Abstract The Beckman Electrolyte 2 Analyzer (E2A) has been studied for its response to
sodium and potassium content in various laboratory prepared pH-adjusted mixtures of metal …
sodium and potassium content in various laboratory prepared pH-adjusted mixtures of metal …
Direct potentiometric measurement of potassium in blood serum with liquid ion-exchange electrode
WM Wise, MJ Kurey, G Baum - Clinical Chemistry, 1970 - academic.oup.com
A new liquid ion-exchange electrode is described which has a selectivity for K+ over Na+ of
93: 1 in 0.1 mol/kg solutions. Its response is Nernstian in the range 5 x 10-4 to 5 x 10-1 mol …
93: 1 in 0.1 mol/kg solutions. Its response is Nernstian in the range 5 x 10-4 to 5 x 10-1 mol …
Determination of sodium with ion-selective electrodes.
GB Levy - Clinical chemistry, 1981 - academic.oup.com
The advent of ion-selective electrodes made possible the potentiometry of sodium in serum
and plasma. These methods were based on dilution of serum, as done in flame photometry …
and plasma. These methods were based on dilution of serum, as done in flame photometry …
Interference from heparin in commercial heparinised tubes in the measurement of plasma sodium by ion selective electrode: a note of caution
SW Mann, A Green - Annals of clinical biochemistry, 1986 - journals.sagepub.com
Method Sodium and potassium concentrations were measured in both whole blood and
plasma from a series of 21 patient samples using a Corning 902 ISE. The difference …
plasma from a series of 21 patient samples using a Corning 902 ISE. The difference …
Reference methods for the determination of sodium, potassium, pH and blood gases with ion-selective electrodes
WR Külpmann - 1991 - degruyter.com
The determination of sodium and potassium in serum will be performed in the near future
mainly by ion-selective electrodes. When the samples are highly diluted before …
mainly by ion-selective electrodes. When the samples are highly diluted before …
[引用][C] Enzymatic determinations of sodium, potassium, and chloride in serum compared with determinations by flame photometry, coulometry, and ion-selective …
J Van Pelt - Clinical chemistry, 1994 - academic.oup.com
The CVs of the enzymatic methods are considerably higher (CV 1.2%; 0.7-1.5%; C” T 1.3-
2.0%), and the CV values are affected by both CV and CIT0 contributions. In addition, the …
2.0%), and the CV values are affected by both CV and CIT0 contributions. In addition, the …
[引用][C] The apparent suppression of Na/K data obtained with ion-selective electrodes is due to junction potential and activity coefficient effects, not bicarbonate binding.
JD Czaban, AD Cormier, KD Legg - Clinical chemistry, 1982 - academic.oup.com
Biomedical, Newton, MA) ion-selective electrode type of analyzer relative to that obtained
with flame photometry. They were concerned because their results were in disagreement …
with flame photometry. They were concerned because their results were in disagreement …