Effect of simulated masticatory loading on the retention of stud attachments for implant overdentures
S Abi Nader, RF De Souza, D Fortin… - Journal of oral …, 2011 - Wiley Online Library
This study assessed the effect of simulated mastication on the retention of two stud
attachment systems for 2‐implants overdentures. Sixteen specimens, each simulating an …
attachment systems for 2‐implants overdentures. Sixteen specimens, each simulating an …
Effect of simulated mastication on the retention of Locator attachments for implant‐supported overdentures: an in vitro pilot study
Purpose Limited information is currently available relative to the effect of masticatory loads
on the retentive properties of Locator attachments. The aims of this in vitro study were to …
on the retentive properties of Locator attachments. The aims of this in vitro study were to …
Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations
JW Choi, JH Bae, CM Jeong, JB Huh - The Journal of prosthetic dentistry, 2017 - Elsevier
Statement of problem Implant angulation should be considered when selecting an
attachment. Some in vitro studies have investigated the relationship between implant …
attachment. Some in vitro studies have investigated the relationship between implant …
Maintenance requirements associated with mandibular implant overdentures: clinical results after first year of service
The aim of this clinical study was to evaluate the prosthodontic maintenance requirements
during the first year of service of mandibular overdentures supported by interforaminal …
during the first year of service of mandibular overdentures supported by interforaminal …
Retention of implant‐supported overdentures at different implant angulations: Comparing Locator and ball attachments
N Sultana, DW Bartlett… - Clinical oral implants …, 2017 - Wiley Online Library
Objectives To assess the effect of implant angulation on the retention of two different
attachment systems for implant‐supported overdentures after a simulated fatigue period of …
attachment systems for implant‐supported overdentures after a simulated fatigue period of …
Retention characteristics of different attachment systems of mandibular overdentures retained by two or three implants.
Purpose: The purpose of this study was to quantify and compare the retentive forces of five
different prosthetic attachment designs on mandibular overdentures retained by two or three …
different prosthetic attachment designs on mandibular overdentures retained by two or three …
In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations
S Maniewicz, I Badoud, FR Herrmann… - Clinical oral implants …, 2020 - Wiley Online Library
Objectives This in vitro study aimed to compare changes in retentive force due to cyclic
dislodging of three novel un‐splinted attachments. Materials and Methods Experimental …
dislodging of three novel un‐splinted attachments. Materials and Methods Experimental …
Testing the retention of attachments for implant overdentures–validation of an original force measurement system
O Fromentin, C Lassauzay, S Abi Nader… - Journal of oral …, 2010 - Wiley Online Library
The aim of this study was to validate an original portable device to measure attachment
retention of implant overdentures both in the lab and in clinical settings. The device was built …
retention of implant overdentures both in the lab and in clinical settings. The device was built …
Methodology for measuring the in vitro seating and unseating forces of prefabricated attachment systems used to retain implant overdentures
A Fakhry, SC Tan, AD Heiner… - … Implant, Esthetic and …, 2010 - Wiley Online Library
Purpose: The purpose of this in vitro investigation was to measure the forces generated
during the continuous seating and unseating of prefabricated attachment systems used to …
during the continuous seating and unseating of prefabricated attachment systems used to …
Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: an in vitro study
J Setz, SH Lee, E Engel - The Journal of prosthetic dentistry, 1998 - Elsevier
Statement of problem. Bar and stud attachments are widely used to stabilize overdentures
on implants in the mandible. There is strong evidence that retention of the attachment is an …
on implants in the mandible. There is strong evidence that retention of the attachment is an …
相关搜索
- retention of attachments implant overdentures
- implant overdenture stud type
- locator attachments simulated mastication
- ball attachments implant angulations
- cyclic dislodging implant overdentures
- mandibular overdentures retention characteristics
- stud attachments implant overdentures
- stud type implant angulations