Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods

A Chromy, L Zalud, P Dobsak, I Suskevic, V Mrkvicova - Springerplus, 2015 - Springer
Limb volume measurements are used for evaluating growth of muscle mass and effectivity of
strength training. Beside sport sciences, it is used eg for detection of oedemas …

Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign …

DK Sukul, PT Den Hoed, EJ Johannes… - Journal of biomedical …, 1993 - Elsevier
Volume changes can be measured either directly by water-displacement volumetry or by
various indirect methods in which calculation of the volume is based on circumference …

Limb Volume Measurements: A Comparison of Circumferential Techniques and Optoelectronic Systems against Water Displacement

G Farina, M Galli, L Borsari, A Aliverti… - Bioengineering, 2024 - mdpi.com
Background. Accurate measurements of limb volumes are important for clinical reasons. We
aimed to assess the reliability and validity of two centimetric and two optoelectronic …

Development and clinical evaluation of a computerized limb volume measurement system (CLEMS)

JH Bednarczyk, C Hershler… - Archives of physical …, 1992 - archives-pmr.org
Limb edema is a common problem in both rehabilitation and acute care settings. In the past,
attempts to determine an optimal management strategy for limb edema have been limited by …

Reliability and validity of measurement tools for residual limb volume in people with limb amputations: a systematic review

L Armitage, L Kark, S Czerniec, LK Kwah - Physical Therapy, 2019 - academic.oup.com
Background Measurements of residual limb volume often guide decisions on the type and
timing of prosthetic prescription. To help inform these decisions, it is important that clinicians …

Validity and reliability of Girth measurement (Circumference measurement) for calculating residual limb volume in below knee amputees

J Boonhong - 2004 - cuir.chula.ac.th
Objective: To assess the validity and reliability of girth measurement for calculating the
residual limb volume. Design: Comparison of girth measurement with gold standard in …

Measuring lower limb circumference and volume–introduction of a novel optical 3D volumetric measurement system

T Tischer, S Oye, A Wolf, F Feldhege… - Biomedical …, 2020 - degruyter.com
This study comprised two experiments:(1) the reliability of a novel optical three-dimensional
(3D) volumetric measurement system (BODYTRONIC® 600) for the assessment of lower …

A new, effective and low-cost three-dimensional approach for the estimation of upper-limb volume

R Buffa, E Mereu, P Lussu, V Succa, T Pisanu, F Buffa… - sensors, 2015 - mdpi.com
The aim of this research was to validate a new procedure (SkanLab) for the three-
dimensional estimation of total arm volume. SkanLab is based on a single structured-light …

Reliability of the inverse water volumetry method to measure the volume of the upper limb

MA Beek, A te Slaa, L van der Laan… - … research and biology, 2015 - liebertpub.com
Background: Lymphedema of the upper extremity is a common side effect of lymph node
dissection or irradiation of the axilla. Several techniques are being applied in order to …

Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume

R Kofman, AM Beekman, CH Emmelot… - Prosthetics and …, 2018 - journals.sagepub.com
Background: Non-contact scanners may have potential for measurement of residual limb
volume. Different non-contact scanners have been introduced during the last decades …