Shock reduction with antitachycardia pacing before and during charging for fast ventricular tachycardias in patients with implantable defibrillators
PD Dallaglio, I Anguera, JBM Ferrer, L Pérez… - Revista Española de …, 2018 - Elsevier
Introduction and objectives Fast ventricular tachycardias in the ventricular fibrillation zone in
patients with an implantable cardioverter-defibrillator are susceptible to antitachycardia …
patients with an implantable cardioverter-defibrillator are susceptible to antitachycardia …
Shock reduction with multiple bursts of antitachycardia pacing therapies to treat fast ventricular tachyarrhythmias in patients with implantable cardioverter defibrillators …
I Anguera, P Dallaglio… - Journal of …, 2015 - Wiley Online Library
Multiple Bursts for Fast Ventricular Tachycardia Introduction An empirical sequence of burst
antitachycardia pacing (ATP) is effective in terminating fast ventricular tachycardias (FVT) in …
antitachycardia pacing (ATP) is effective in terminating fast ventricular tachycardias (FVT) in …
Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging
W Schoels, D Steinhaus, WB Johnson, G O'Hara… - Heart Rhythm, 2007 - Elsevier
BACKGROUND: Previous studies in implantable cardioverter-defibrillator (ICD) patients
demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular …
demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular …
A randomized study to compare ramp versus burst antitachycardia pacing therapies to treat fast ventricular tachyarrhythmias in patients with implantable cardioverter …
MM Gulizia, L Piraino, M Scherillo… - Circulation …, 2009 - Am Heart Assoc
Background—In patients with implantable cardioverter-defibrillators (ICDs), antitachycardia
pacing (ATP) is highly effective in terminating fast ventricular tachycardias (FVTs) and lowers …
pacing (ATP) is highly effective in terminating fast ventricular tachycardias (FVTs) and lowers …
The benefit of a second burst antitachycardia sequence for fast ventricular tachycardia in patients with implantable cardioverter defibrillators
I Anguera, P Dallaglio, X Sabate… - Pacing and Clinical …, 2014 - Wiley Online Library
Background In patients with implantable cardioverter defibrillators (ICDs), an empirical burst
of antitachycardia pacing (ATP) is moderately effective in terminating fast ventricular …
of antitachycardia pacing (ATP) is moderately effective in terminating fast ventricular …
Efficacy of Anti-Tachycardia Pacing for Terminating Fast Ventricular Tachycardia in Japanese Implantable Cardioverter Defibrillator Patients–Primary Results of the …
T Watanabe, K Inoue, K Kashiwase, T Mine… - Circulation …, 2014 - jstage.jst.go.jp
Background: Anti-tachycardia pacing (ATP) delivered by implantable cardioverter
defibrillators (ICD) safely avoids painful shocks with minimum risk of tachycardia …
defibrillators (ICD) safely avoids painful shocks with minimum risk of tachycardia …
Antitachycardia pacing for very fast ventricular tachycardia and low-energy shock for ventricular arrhythmias in patients with implantable defibrillators
Implantable cardioverter-defibrillator therapy in the form of high-energy shock (HES) is
associated with adverse effects. This study evaluated an alternative therapy to HES …
associated with adverse effects. This study evaluated an alternative therapy to HES …
Effect of elevated heart rate preceding the onset of ventricular tachycardia on antitachycardia pacing effectiveness in patients with implantable cardioverter …
C Kouakam, B Lauwerier, D Klug, M Jarwe… - The American journal of …, 2003 - Elsevier
The incorporation of antitachycardia pacing (ATP) into implantable cardioverter defibrillators
(ICDs) has provided a better tolerated alternative to shocks. ATP has been shown to be …
(ICDs) has provided a better tolerated alternative to shocks. ATP has been shown to be …
Additional antitachycardia pacing programming strategies further reduce unnecessary implantable cardioverter-defibrillator shocks
Background Antitachycardia pacing (ATP) is routinely used to terminate ventricular
tachyarrhythmias (VTs). However, little guidance exists on the most effective programming of …
tachyarrhythmias (VTs). However, little guidance exists on the most effective programming of …
Impact of accelerated ventricular tachyarrhythmias on mortality in patients with implantable cardioverter-defibrillator therapy
C Schukro, L Leitner, J Siebermair, T Pezawas… - International journal of …, 2013 - Elsevier
Background Anti-tachycardia pacing (ATP) and shock delivery may induce or accelerate
tachyarrhythmias in patients with implantable cardioverter-defibrillator (ICD). We …
tachyarrhythmias in patients with implantable cardioverter-defibrillator (ICD). We …
相关搜索
- ventricular tachyarrhythmias cardioverter defibrillators
- implantable defibrillators shock reduction
- ventricular tachycardias shock reduction
- implantable defibrillators ventricular tachycardias
- ventricular tachycardia effectiveness in patients
- cardioverter defibrillators effectiveness in patients
- ventricular tachycardia heart rate
- cardioverter defibrillators shock reduction
- ventricular tachycardia cardioverter defibrillators
- ventricular tachyarrhythmias shock reduction
- implantable defibrillators ventricular arrhythmias
- mortality in patients cardioverter defibrillator