Generation of Rapid and High-Quality Serum by Recombinant Prothrombin Activator Ecarin (RAPClot™)

KN Zhao, G Dimeski, P Masci, L Johnson, J Wang… - Biomolecules, 2024 - mdpi.com
We recently reported the potential application of recombinant prothrombin activator ecarin
(RAPClot™) in blood diagnostics. In a new study, we describe RAPClot™ as an additive to …

Potential Application of Recombinant Snake Prothrombin Activator Ecarin in Blood Diagnostics

KN Zhao, P Masci, G Dimeski, L Johnson, M Grant… - Biomolecules, 2022 - mdpi.com
We describe here the purification and cloning of a codon-optimized form of the snake
prothrombin activator ecarin from the saw scaled viper (Echis carinatus) expressed in …

Next-generation rapid serum tube technology using prothrombin activator coagulant: fast, high-quality serum from normal samples

KN Zhao, G Dimeski, J De Jersey… - Clinical Chemistry and …, 2019 - degruyter.com
Background Incomplete blood clotting or latent clotting in serum is a common laboratory
problem, especially for patients on anticoagulant therapy or when serum tubes are …

Expression and characterization of recombinant ecarin

A Jonebring, U Lange, E Bucha, J Deinum, M Elg… - The Protein …, 2012 - Springer
The snake venom protease ecarin from Echis carinatus was expressed in stable transfected
CHO-S cells grown in animal component free cell culture medium. Recombinant ecarin (r …

Ecarin clotting time is sensitive to heparinoids: comparison of two different techniques

M Demir, O Iqbal, B Untch… - Clinical and Applied …, 2001 - journals.sagepub.com
Ecarin clotting time (ECT) is currently developed for the specific monitoring of antithrombin
drugs, such as hirudin, argatroban, and hirulog. Aqueous reagent and dry chemistry …

Monitoring of recombinant hirudin: assessment of a plasma-based ecarin clotting time assay

B Pötzsch, S Hund, K Madlener, C Unkrig… - Thrombosis research, 1997 - Elsevier
Assay conditions of a plasma-based ecarin clotting time (ECT) were evaluated and the
precision of the ECT in monitoring plasma levels of r-hirudin assessed. The snake venom …

Evaluation of the Greiner bio-one serum separator BCA fast clot tube

G Dimeski, J Johnston, PP Masci, KN Zhao… - Clinical Chemistry and …, 2017 - degruyter.com
Background: Current commercial tubes have difficulties in producing “true” serum from all
blood samples even within the recommended clotting times. Hence, Becton Dickinson (BD) …

Ecarin chromogenic assay–a new method for quantitative determination of direct thrombin inhibitors like hirudin

U Lange, G Nowak, E Bucha - Pathophysiology of haemostasis and …, 2003 - karger.com
A new sensitive and precise method for quantitative determination of direct thrombin
inhibitors is described, the ecarin chromogenic assay (ECA). Ecarin is used as the specific …

[PDF][PDF] Rapid serum tube technology overcomes problems associated with use of anticoagulants

KN Zhao, G Dimeski, J de Jersey, LA Johnson… - Biochemia …, 2019 - hrcak.srce.hr
Original articles Page 1 https://doi.org/10.11613/BM.2019.030706 Biochem Med (Zagreb)
2019;29(3):030706 1 Abstract Introduction: Failure to obtain complete blood clotting in serum is …

Activated partial thromboplastin time is more sensitive than ecarin clotting time for monitoring low doses of desirudin

E Mazoyer, L Drouet, B Delahousse… - Thrombosis …, 2002 - thrombosisresearch.com
Recently, low-dose hirudin has been suggested for the prevention of deep venous
thrombosis (DVT) after orthopaedic surgery in high-risk patients [1]. Monitoring of …