Validation of a New Ankle Brachial Index Measurement System Using Pulse Wave Velocity

JD Romero-Ante, E Chicharro-Luna… - Biosensors, 2024 - mdpi.com
Peripheral artery disease (PAD) is a common circulatory disorder characterized by the
accumulation of fats, cholesterol, and other substances in the arteries that restrict blood flow …

Oscillometric measurement of the ankle-brachial index and the estimated carotid-femoral pulse wave velocity improves the sensitivity of an automated device in …

K Fendrik, K Biró, D Endrei, K Koltai… - Frontiers in …, 2023 - frontiersin.org
Background and aims To overcome the time and personnel constraints of the Doppler
method, automated, four-limb blood pressure monitors were recently developed. Their …

Development of a Non-invasive System to Estimate Ankle Brachial Index

XJA Tan, KP Chua, JYA Foo - … Engineering: ICBME 2013, 4th to 7th …, 2014 - Springer
Peripheral arterial disease (PAD) occurs when plaque builds up in the artery walls and limits
the blood flow in the legs which may subsequently cause muscle pains. It is a highly …

Automated measurements of ankle-brachial index: a narrative review

A Danieluk, S Chlabicz - Journal of Clinical Medicine, 2021 - mdpi.com
Peripheral artery disease (PAD) is an atherosclerotic disease that causes obstruction in
lower limb arteries. It increases cardiovascular risk even in asymptomatic patients. Accurate …

Ankle Doppler for cuffless ankle brachial index estimation and peripheral artery disease diagnosis independent of diabetes

AD Rodway, D Cheal, C Allan, F Pazos-Casal… - Journal of clinical …, 2022 - mdpi.com
Ankle brachial pressure index (ABPI) is the first-line test to diagnose peripheral artery
disease (PAD). Its adoption in clinical practice is poor and its validity, particularly in diabetes …

Brachial ankle pulse wave velocity: a classic but still important method

H Hayashi, M Fujita - Internal Medicine, 2013 - jstage.jst.go.jp
In 1892, William Osler proposed that “a man is only as old as his arteries.” As implicated by
this memorable statement, cardiovascular disease has become one of the major disorders in …

Automated oscillometric determination of the ankle–brachial index provides accuracy necessary for office practice

JA Beckman, CO Higgins, M Gerhard-Herman - Hypertension, 2006 - Am Heart Assoc
Peripheral arterial disease (PAD) remains underdiagnosed by primary care and
cardiovascular physicians. The office-based assessment of PAD is limited by the need for …

Combination of pulse volume recording (PVR) parameters and ankle–brachial index (ABI) improves diagnostic accuracy for peripheral arterial disease compared with …

T Hashimoto, S Ichihashi, S Iwakoshi… - Hypertension …, 2016 - nature.com
The ankle–brachial index (ABI) measurement is widely used as a screening tool to detect
peripheral arterial disease (PAD). With the advent of the oscillometric ABI device …

Ankle/brachial index in the primary care setting

JK Raines, J Farrar, K Noicely, J Pena… - Vascular and …, 2004 - journals.sagepub.com
Peripheral arterial disease (PAD) is an underdiagnosed circulatory problem in the primary
care setting. Individuals are at increased risk for cardiovascular disease; therefore, there is …

Automated ankle-brachial pressure index measurement by clinical staff for peripheral arterial disease diagnosis in nondiabetic and diabetic patients

C Clairotte, S Retout, L Potier, R Roussel… - Diabetes …, 2009 - Am Diabetes Assoc
OBJECTIVE Peripheral arterial disease (PAD) is a prognostic marker in cardiovascular
disease. The use of Doppler-measured ankle-brachial pressure index (Dop-ABI) for PAD …