Validating volume flow measurements from a novel semiautomated four-dimensional Doppler ultrasound scanner

F Forsberg, AD Stein, JB Liu, X Deng, W Ackerman… - Academic radiology, 2006 - Elsevier
RATIONALE AND OBJECTIVES: Accurate measurement of blood volume flow (in ml/min) is
an important clinical goal. This project compared in vitro and in vivo volume flow …

Mean volume flow estimation in pulsatile flow conditions

MS Richards, OD Kripfgans, JM Rubin, AL Hall… - Ultrasound in medicine …, 2009 - Elsevier
To verify a previously reported three-dimensional (3D) ultrasound method for the
measurement of time-average volumetric blood flow, experiments were performed under …

Volumetric flow estimation in vivo and in vitro using pulsed-Doppler ultrasound

CK Holland, MJ Clancy, KJW Taylor… - Ultrasound in medicine …, 1996 - Elsevier
The measurement of volumetric blood flow in small vessels in vitro and in vivo poses a
significant technological challenge. In this study, two pulsatile flow models were developed …

A novel in vivo procedure for volumetric flow measurements

R Jenni, F Matthews, SV Aschkenasy, M Lachat… - Ultrasound in medicine …, 2004 - Elsevier
We report on a novel procedure for invasive volumetric blood flow measurements using a
commercially available Doppler flow wire system, which could, until now, only measure flow …

Measurement of volumetric flow

OD Kripfgans, JM Rubin, AL Hall… - Journal of ultrasound …, 2006 - Wiley Online Library
Objective. The purpose of this study was to evaluate a 3‐dimensional (3D) sonographic
method for the measurement of volumetric flow under conditions of known flow rates and …

Accuracy and reproducibility of a novel dynamic volume flow measurement method

S Ricci, M Cinthio, ÅR Ahlgren, P Tortoli - Ultrasound in Medicine & Biology, 2013 - Elsevier
In clinical practice, blood volume flow (BVF) is typically calculated assuming a perfect
parabolic and axisymmetric velocity distribution. This simple approach cannot account for …

In vitro validation of volumetric blood flow measurement using Doppler flow wire

R Jenni, PA Kaufmann, Z Jiang, C Attenhofer… - Ultrasound in medicine …, 2000 - Elsevier
Determination of any volumetric blood flow requires assessment of mean blood flow velocity
and vessel cross-sectional area. For evaluation of coronary blood flow and flow reserve …

Time-averaged mean velocity for volumetric blood flow measurements: an in vitro model validation study using physiological femoral artery flow waveforms

RD Walker, RE Smith, SB Sherriff, RFM Wood - Ultrasound in medicine & …, 1999 - Elsevier
This study assesses the accuracy of the volume flow measurement of the ATL HDI 3000
duplex ultrasound scanner using a model of the femoral arterial circulation. The beam profile …

Accuracy of 3‐Dimensional Color Doppler‐Derived Flow Volumes With Increasing Image Depth

J Pemberton, L Hui, M Young, X Li… - Journal of ultrasound …, 2005 - Wiley Online Library
Objective We and others have reported on the use of digital color Doppler sonography from
real‐time 3‐dimensional (3D) echocardiography and its use in accurately calculating …

Forward-viewing estimation of 3D blood flow velocity fields by intravascular ultrasound: Influence of the catheter on velocity estimation in stenoses

S Kim, B Jing, BD Lindsey - Ultrasonics, 2021 - Elsevier
Coronary artery disease is the most common type of cardiovascular disease, affecting> 18
million adults, and is responsible for> 365 k deaths per year in the US alone. Wall shear …