Cortical source localization in EEG frequency analysis
W Xie, JE Richards - The Oxford Handbook of EEG Frequency, 2022 - books.google.com
EEG signals recorded via electrodes placed on the scalp represent the postsynaptic
potentials generated by mass synchronized pyramidal neurons perpendicular to the cortical …
potentials generated by mass synchronized pyramidal neurons perpendicular to the cortical …
EEG source localization and imaging using multiple signal classification approaches
Equivalent current dipoles are a powerful tool for modeling focal sources. The dipole is often
sufficient to adequately represent sources of measured scalp potentials, even when the area …
sufficient to adequately represent sources of measured scalp potentials, even when the area …
[HTML][HTML] EEG source localization: Sensor density and head surface coverage
J Song, C Davey, C Poulsen, P Luu, S Turovets… - Journal of neuroscience …, 2015 - Elsevier
Background The accuracy of EEG source localization depends on a sufficient sampling of
the surface potential field, an accurate conducting volume estimation (head model), and a …
the surface potential field, an accurate conducting volume estimation (head model), and a …
EEG source imaging
Objective: Electroencephalography (EEG) is an important tool for studying the temporal
dynamics of the human brain's large-scale neuronal circuits. However, most EEG …
dynamics of the human brain's large-scale neuronal circuits. However, most EEG …
Study on EEG source localization in frequency domain
X Zheng, B Wan - 2005 IEEE Engineering in Medicine and …, 2006 - ieeexplore.ieee.org
This article deals with a new approach based on predominant frequency that combines EEG
source localization methods with standard frequency analysis of multi-electrode EEGs. First …
source localization methods with standard frequency analysis of multi-electrode EEGs. First …
Anatomically informed basis functions for EEG source localization: combining functional and anatomical constraints
Distributed linear solutions have frequently been used to solve the source localization
problem in EEG. Here we introduce an approach based on the weighted minimum norm …
problem in EEG. Here we introduce an approach based on the weighted minimum norm …
Dipole localization using simulated intracerebral EEG
N Chang, R Gulrajani, J Gotman - Clinical neurophysiology, 2005 - Elsevier
OBJECTIVE: In the clinical interpretation of intracerebral EEGs, epileptic foci are commonly
identified by visually analyzing the amplitude of the potentials. This is potentially misleading …
identified by visually analyzing the amplitude of the potentials. This is potentially misleading …
Electroencephalography and high-density electrophysiological source localization
DA Pizzagalli - Handbook of psychophysiology, 2007 - books.google.com
In 1924, Hans Berger, a German psychiatrist, performed the first electroencephalographic
(EEG) recording in humans (Berger, 1929), a discovery that was initially greeted with great …
(EEG) recording in humans (Berger, 1929), a discovery that was initially greeted with great …
[引用][C] EEG source localization
S Sanei, JA Chambers - EEG signal processing, 2007 - Wiley Online Library
This chapter contains sections titled: Introduction Overview of the Traditional Approaches
Determination of the Number of Sources Summary and Conclusions
Determination of the Number of Sources Summary and Conclusions