Standardized imaging for aortic annular sizing: implications for transcatheter valve selection

AM Kasel, S Cassese, S Bleiziffer, M Amaki… - JACC: Cardiovascular …, 2013 - jacc.org
The safety and efficacy of transcatheter aortic valve replacement procedures are directly
related to proper imaging. This report revisits the existing noninvasive and invasive …

Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation

R Gurvitch, JG Webb, R Yuan, M Johnson… - JACC: Cardiovascular …, 2011 - jacc.org
Objectives: This study sought to determine the most reproducible multidetector computed
tomography (MDCT) measurements of the aortic annulus and to determine methods to …

Feasibility, accuracy, and reproducibility of aortic annular and root sizing for transcatheter aortic valve replacement using novel automated three-dimensional …

EA Prihadi, PJ van Rosendael, EM Vollema… - Journal of the American …, 2018 - Elsevier
Background In transcatheter aortic valve replacement (TAVR), multi–detector row computed
tomography (MDCT) is currently the standard imaging modality for correct prosthesis sizing …

Computed tomography–based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: Comparison with transesophageal …

AB Willson, JG Webb, M Freeman, DA Wood… - Journal of …, 2012 - Elsevier
BACKGROUND: Computed tomography (CT) annular measurements are predictive of
paravalvular regurgitation after transcatheter aortic valve replacement (TAVR) which is a …

Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography

OK Khalique, SK Kodali, JM Paradis… - Circulation …, 2014 - Am Heart Assoc
Background—Previous studies have shown cross-sectional 3-dimensional (3D)
transesophageal echocardiographic (TEE) measurements to severely underestimate …

Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve …

E Altiok, R Koos, J Schröder, K Brehmer, S Hamada… - Heart, 2011 - heart.bmj.com
Aims Different two-dimensional (2D) and three-dimensional (3D) imaging techniques are
used for procedure planning and selection of prosthesis size before transcatheter aortic …

Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of …

H Jilaihawi, M Kashif, G Fontana, A Furugen… - Journal of the American …, 2012 - jacc.org
Objectives: In an effort to define the gold standard for annular sizing for transcatheter aortic
valve replacement (TAVR), we sought to critically analyze and compare the predictive value …

Role of multislice computed tomography in transcatheter aortic valve replacement

DA Wood, LF Tops, JR Mayo, S Pasupati… - The American journal of …, 2009 - Elsevier
Transcatheter aortic valve replacement (TAVR) required precise knowledge of the anatomic
dimensions and physical characteristics of the aortic valve, annulus, and aortic root. Most …

The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective …

RK Binder, JG Webb, AB Willson, M Urena… - Journal of the American …, 2013 - jacc.org
Objectives: This study prospectively investigated the impact of integration of a multidetector
computed tomography (MDCT) annular area sizing algorithm on transcatheter aortic valve …

Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation

D Messika-Zeitoun, JM Serfaty, E Brochet… - Journal of the American …, 2010 - jacc.org
Objectives: We sought to compare 3 methods of measurements of the aortic annulus,
transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and …