The service life of implant-retained overdenture attachment systems

MN Pigozzo, MF Mesquita, GEP Henriques… - The Journal of prosthetic …, 2009 - Elsevier
STATEMENT OF PROBLEM: Implant-retained overdentures are a treatment option for
patients who are not satisfied with conventional complete dentures. Although implant …

Retention force and fatigue strength of overdenture attachment systems

DM Botega, MF Mesquita… - Journal of oral …, 2004 - Wiley Online Library
summary This study evaluated retention force and fatigue resistance of two overdenture
attachment systems. Twenty samples (O‐ring and Bar‐Clip) from two manufacturers …

[HTML][HTML] Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study

C Aroso, AS Silva, R Ustrell, JM Mendes… - The journal of …, 2016 - ncbi.nlm.nih.gov
PURPOSE This in vitro study investigated and compared the durability and retention of three
types of attachments. MATERIALS AND METHODS Three commercially available …

Comparative study of four retentive anchor systems for implant supported overdentures–retention force changes

S Bayer, D Steinheuser, M Grüner, L Keilig… - …, 2009 - Wiley Online Library
Objectives: Wear of attachments leads to a loss of retention and potentially reduces the
function of complete dentures. This study evaluated the retention force changes of different …

Attachment systems for implant retained overdentures: a literature review

T Trakas, K Michalakis, K Kang, H Hirayama - Implant dentistry, 2006 - journals.lww.com
This article presents a comparison between different attachment systems used to retain and
support maxillary and mandibular overdentures in completely edentulous patients. A …

The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system

SA Al-Ghafli, KX Michalakis, H Hirayama… - Journal of Prosthetic …, 2009 - thejpd.org
Purpose. The purpose of this in vitro study was to investigate the effect of cyclic
dislodgement on the retention of an overdenture attachment system when 2 implants were …

An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures

T Shastry, NM Anupama, S Shetty… - The Journal of Indian …, 2016 - journals.lww.com
Aim: The aim of this in vitro study was to compare the change in the retentive force and
removal torque of three attachment systems during simulation of insertion-removal cycles …

In vitro changes in clips and bars used to retain implant overdentures

JN Walton, ND Ruse - The Journal of prosthetic dentistry, 1995 - Elsevier
Although implant-retained overdentures are a less expensive alternative to fixed implant-
supported prostheses in certain situations, problems with retentive clips fracturing and …

[HTML][HTML] Comparison of the retentive properties of six prefabricated post overdenture attachment systems

DD Epstein, PL Epstein, BI Cohen… - The Journal of prosthetic …, 1999 - Elsevier
Statement of problem. There are few research studies concerning prefabricated posts
overdenture attachment systems using multiple pull cycles. Purpose. This study tested 6 …

[HTML][HTML] In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®

N Mínguez-Tomás… - Journal of clinical and …, 2018 - ncbi.nlm.nih.gov
Background It is necessary to know the in vitro behavior of different attachment systems to
be used clinically. The evolution of retention capacity over 10 years (14,600 insertion/de …