Native tissue harmonic imaging: basic principles and clinical applications
TS Desser, T Jedrzejewicz, C Bradley - Ultrasound Quarterly, 2000 - journals.lww.com
Native Tissue Harmonic Imaging: Page 1 Ultrasound Quarterly Vol. 16, No. 1, pp. 40–48 O 2000
Lippincott Williams & Wilkins, Inc., Philadelphia CME ARTICLE Native Tissue Harmonic …
Lippincott Williams & Wilkins, Inc., Philadelphia CME ARTICLE Native Tissue Harmonic …
[PDF][PDF] Aberration and second harmonic imaging
Simulations are presented which indicate that imag-ing at the second-harmonic frequency
does not solve the problem of ultrasonic wave aberration. The nonlinearity of acoustic wave …
does not solve the problem of ultrasonic wave aberration. The nonlinearity of acoustic wave …
Nonlinear acoustics in diagnostic ultrasound
FA Duck - Ultrasound in medicine & biology, 2002 - Elsevier
The propagation of ultrasonic waves is nonlinear. Phenomena associated with the
propagation of diagnostic ultrasound pulses cannot be predicted using linear assumptions …
propagation of diagnostic ultrasound pulses cannot be predicted using linear assumptions …
Nonlinear acoustics in tissue harmonic imaging
M Averkiou - The Journal of the Acoustical Society of America, 2003 - pubs.aip.org
In recent years the interest in nonlinear acoustics has dramatically increased in diagnostic
ultrasound. There are two main areas where nonlinear acoustics is used in medical imaging …
ultrasound. There are two main areas where nonlinear acoustics is used in medical imaging …
Tissue harmonic imaging: what is it and how does it work?
B Ward, T Whittingham - BMUS Bulletin, 1999 - journals.sagepub.com
Over the last year or so, several major manufacturers of ultrasound scanners have brought
out machines equipped with a new grey-scale imaging option called" tissue harmonic …
out machines equipped with a new grey-scale imaging option called" tissue harmonic …
[引用][C] 2263: Tissue harmonic imaging for musculoskeletal ultrasound
TP Gauthier, MT van Holsbeeck - Ultrasound in Medicine and …, 2006 - umbjournal.org
Methods: A numerical simulation was used to predict harmonic waveform shape given
ultrasound scanners signal path limitation. It was further used to design ideal THI waveforms …
ultrasound scanners signal path limitation. It was further used to design ideal THI waveforms …
Characterization of harmonic pressure field: Application to medical ultrasound imaging
M Bahaz, K Benmahammed, N Benoudjit… - … Journal of Computer …, 2009 - cspub-ijcisim.org
Over the last few decades medical ultrasound has become an established diagnostic and
therapeutic tool since it produces detailed and high resolution images of tissues in human …
therapeutic tool since it produces detailed and high resolution images of tissues in human …
[PDF][PDF] TIME REVERSAL OF ACOUSTIC WAVES IN THE NONLINEAR REGIME: APPLICATION TO HARMONIC IMAGING IN MEDICAL ULTRASOUND
Harmonic imaging coupled to the use of contrast agents is a topic of wide interest in
ultrasonic medical imaging. Images are built at twice the excitation frequency that …
ultrasonic medical imaging. Images are built at twice the excitation frequency that …
[引用][C] Technical aspects of tissue harmonic imaging.
M Pasławski, W Krupski… - American Journal of … - International Scientific Information …
Physics of tissue harmonic imaging
TL Szabo - The Journal of the Acoustical Society of America, 2003 - pubs.aip.org
Tissue harmonic imaging is used on almost all modern diagnostic ultrasound equipment.
The clinical success of this modality involves a combination of fortuitous factors. The …