[HTML][HTML] Ischemia-modified albumin: Crosstalk between fatty acid and cobalt binding
Myocardial ischemia is difficult to diagnose effectively with still few well-defined biochemical
markers for identification in advance, or in the absence of myocardial necrosis.“Ischemia …
markers for identification in advance, or in the absence of myocardial necrosis.“Ischemia …
Albumin cobalt binding and ischemia modified albumin generation: an endogenous response to ischemia?
G Lippi, M Montagnana… - International …, 2006 - internationaljournalofcardiology.com
Myocardial ischemia has become the leading cause of mortality in western countries and
this unfavorable trend is unlikely to reverse in the near future. The events progression …
this unfavorable trend is unlikely to reverse in the near future. The events progression …
Ischemia‐Modified Albumin: Origins and Clinical Implications
Albumin is one of the most abundant proteins in the body of mammals: about 40% of its pool
is located in the intravascular space and the remainder is found in the interstitial space. The …
is located in the intravascular space and the remainder is found in the interstitial space. The …
[PDF][PDF] Ischemia modified albumin: is this marker of ischemia ready for prime time use
E Sbarouni, P Georgiadou, DT Kremastinos… - Hellenic J …, 2008 - hellenicjcardiol.org
First identified in the early 1990s, IMA is produced when ischemia stresses released from
hypoxic heart tissue induce modification of circulating albumin. 5, 6 The amino terminal end …
hypoxic heart tissue induce modification of circulating albumin. 5, 6 The amino terminal end …
Development of an albumin copper binding (ACuB) assay to detect ischemia modified albumin
JE Eom, E Lee, KH Jeon, J Sim, M Suh, GJ Jhon… - Analytical …, 2014 - Springer
Myocardial ischemia (MI) induces many changes in the body, including pH decrease and
electrolyte imbalance. No obvious symptoms of MI appear until irreversible cellular injuries …
electrolyte imbalance. No obvious symptoms of MI appear until irreversible cellular injuries …
Clinical and analytical review of ischemia‐modified albumin measured by the albumin cobalt binding test
FS Apple - Advances in Clinical Chemistry, 2005 - Elsevier
Publisher Summary The chapter presents a general overview of the clinical and analytical
issues pertaining to the albumin–cobalt binding (ACB) test that measures ischemia-modified …
issues pertaining to the albumin–cobalt binding (ACB) test that measures ischemia-modified …
Effect of temperature on albumin cobalt binding and its influence on ischemia-modified albumin levels in patients with suspected acute coronary syndrome.
BS Hausen, C Signor, H Kober, E Tatsch… - Clinical …, 2012 - europepmc.org
Background Ischemia-modified albumin (IMA) has been shown to be a rapidly rising and
sensitive biochemical marker especially for the diagnosis of myocardial ischemia. The aim of …
sensitive biochemical marker especially for the diagnosis of myocardial ischemia. The aim of …
Ischemia modified albumin changes–review and clinical implications
E Sbarouni, P Georgiadou, V Voudris - Clinical Chemistry and …, 2011 - degruyter.com
Ischemia modified albumin (IMA), as measured using the albumin cobalt binding test, is
currently the most promising biomarker for early detection of ischemia before the onset of …
currently the most promising biomarker for early detection of ischemia before the onset of …
Allosteric inhibition of cobalt binding to albumin by fatty acids: implications for the detection of myocardial ischemia
J Lu, AJ Stewart, PJ Sadler, TJT Pinheiro… - Journal of Medicinal …, 2012 - ACS Publications
The biomarker “ischemia-modified albumin”(IMA), measured by the albumin–cobalt-binding
assay (ACB assay), is the only FDA-approved biomarker for early diagnosis of myocardial …
assay (ACB assay), is the only FDA-approved biomarker for early diagnosis of myocardial …
Effect of albumin concentration and serum matrix on ischemia-modified albumin
A Haklıgör, A Kösem, M Şeneş, D Yücel - Clinical biochemistry, 2010 - Elsevier
OBJECTIVES:: There is concern that ischemia-modified albumin (IMA) levels measured by
albumin cobalt binding (ACB) assay reflect mainly albumin concentrations rather than …
albumin cobalt binding (ACB) assay reflect mainly albumin concentrations rather than …