Determination of the absorbed dose to water for medium‐energy x‐ray beams using Fricke dosimetry

PH Rosado, C Salata, MG David, A Mantuano… - Medical …, 2020 - Wiley Online Library
Purpose For x‐ray beams in the low and medium energy range, reference dosimetry is
established in terms of air kerma. Fricke dosimetry has shown great potential in the absolute …

Determination of absorbed dose to water with ionisation chambers calibrated in free air for medium-energy x-rays

J Seuntjens, H Thierens… - Physics in Medicine …, 1988 - iopscience.iop.org
In order to determine absorbed dose to water from an in-phantom measurement by an
ionisation chamber, three corrections need to be applied:(a) the ratio of water and air mass …

Linearity and reproducibility response of Fricke dosimetry for low energy X-Ray beam

A Mantuano, GJ De Amorim, MG David… - Journal of Physics …, 2018 - iopscience.iop.org
The Fricke dosimeter is the most used, liquid chemical dosimeter. It has been shown to be a
feasible option for the absorbed dose standard. The present work aims to determinate a …

A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams

R Hill, L Holloway, C Baldock - Physics in Medicine & Biology, 2005 - iopscience.iop.org
Solid phantoms are widely used in radiation therapy for both relative and reference
dosimetry. Two water equivalent phantoms, RMI-457 Solid Water and Plastic Water, were …

Study of the formalism used to determine the absorbed dose for low-energy x-ray beams

U Chica, M Anguiano, AM Lallena - Physics in Medicine & …, 2008 - iopscience.iop.org
We have studied the procedure commonly recommended by dosimetry protocols for the
determination of the absorbed dose in water for low-energy x-rays beams, generated with …

Monte Carlo studies on dose conversion factors from graphite to water for high energy X-ray beams

YH Kim, CY Yi, IJ Kim, BC Kim, JH Kim… - Radiation Physics and …, 2020 - Elsevier
An evaluation of the dose conversion factor from graphite to water is essential to measure
the absorbed dose to water using a graphite calorimeter. However, it is difficult to obtain the …

[HTML][HTML] Bilateral comparison of the absorbed dose to water in high energy X-ray beams between the KRISS and the NMIJ

IJ Kim, BC Kim, CY Yi, M Shimizu, Y Morishita… - Nuclear Engineering …, 2020 - Elsevier
Abstract The Korea Research Institute of Standards and Science (KRISS) established a new
standard of the absorbed dose to water in LINAC X-ray beams. To confirm the equivalence …

Investigation of the chamber correction factor (kch) for the UK secondary standard ionization chamber (NE2561/NE2611) using medium-energy x-rays

KE Rosser - Physics in Medicine & Biology, 1998 - iopscience.iop.org
This paper evaluates the characteristics of ionization chambers for the measurement of
absorbed dose to water for medium-energy x-rays. The values of the chamber correction …

Monte Carlo and 60Co‐based kilovoltage x‐ray dosimetry methods

MJ Lawless, L Dimaso, B Palmer, J Micka… - Medical …, 2018 - Wiley Online Library
Purpose This work seeks to investigate new methods to determine the absorbed dose to
water from kilovoltage x rays. Current methods are based on measurements in air and rely …

A method to determine the water kerma in a phantom for x-rays with energies up to 40 keV

T Schneider - Metrologia, 2009 - iopscience.iop.org
In brachytherapy, as in any form of radiation therapy, accurate dosimetry in terms of
absorbed dose to water is required. The output of brachytherapy sources has, up to now …