Study on the sensitivity of a volumetric modulated arc therapy plan verification equipment on multi-leaf collimator opening and closing errors and its gamma pass rate …

J Hu, L Zou, S Gu, N Wang, F Cui, S Zhang… - Sheng wu yi xue …, 2023 - europepmc.org
为探讨计划验证设备用于容积旋转调强放疗 (VMAT) 计划验证的 γ 通过率限值及其对多叶准直
器 (MLC) 开合误差的敏感性, 本研究选取 50 例含顺时针和逆时针两个全弧的鼻咽癌 VMAT …

[HTML][HTML] 容积旋转调强放疗计划验证设备对多叶准直器开合误差的敏感性及其伽马通过率限值研究

金有胡, 炼邹, 少娴顾, 宁宇王, 凤洁崔… - Sheng Wu Yi Xue …, 2023 - ncbi.nlm.nih.gov
为探讨计划验证设备用于容积旋转调强放疗( VMAT) 计划验证的γ 通过率限值及其对多叶准直
器( MLC) 开合误差的敏感性, 本研究选取50 例含顺时针和逆时针两个全弧的鼻咽癌VMAT …

Effect of the setup error on the dosimetric verification for the volumetric modulated arc therapy

X Sun, L Tan, K Ma, F Xiao - Chinese Journal of Radiation …, 2014 - pesquisa.bvsalud.org
Objective To evaluate the effect of the setup error on the dosimetric verification for the
nasopharyngeal carcinoma patients and cervical carcinoma patients treated with volumetric …

The characteristics and clinical application of the ArcCHECK diode array for volumetric-modulated arc therapy verification

C Li, G LI, C JI, J Xiao, C Guo… - Chinese Journal of …, 2013 - pesquisa.bvsalud.org
Objective To evaluate the characteristics and clinical suitability of the ArcCHECK diode array
for volumetric-modulated arc therapy (VMAT) verification. Methods The intrinsic sensitivity …

Study on the sensitivity of different 3D detectors to MLC positioning errors in volumetric modulated arc therapy (VMAT) plan for nasopharyngeal carcinoma

P ZHANG, B YAN, X XUE, A WU - Chinese Journal of …, 2019 - pesquisa.bvsalud.org
Objective To compare the sensitivity of Deha4 and ArcCHECK 3D detectors to detect the
multi-leaf collimator (MLC) positioning errors in the dose verification of volumetric modulated …

The sensitivity of patient-specific VMAT QA to MLC positioning errors

Q Wang, J Dai, K Zhang… - Chinese Journal of …, 2013 - pesquisa.bvsalud.org
Objective To evaluate the sensitivity of patient-specific volumetric-modulated arc therapy
(VMAT) quality assurance (QA) to minor multileaf collimator (M LC) positioning errors …

[PDF][PDF] Effects of high-resolution measurements between different multi-row detectors on volumetric modulated arc therapy patient-specific quality assurance

Y Kunii, Y Tanabe, A Higashi, A Nakamoto… - International Journal of …, 2023 - sid.ir
Background: This study aimed to evaluate the optimal criteria and conditions in which single-
measurement (SM) and high-resolution measurement (HM) provide a similar evaluation …

[PDF][PDF] 多叶准直器位置误差对静态野调强放疗计划验证通过率影响的研究

王猛 - 中国医疗设备, 2016 - cs.china-cmd.org
目的通过实验分析多叶准直器(Multi-leaf Collimator, MLC) 位置误差对静态野调强放疗(IMRT)
计划验证通过率的影响. 方法选取8 例鼻咽癌IMRT 计划, 通过计划系统设置为每个病例计划的 …

[HTML][HTML] Effect of Multileaf Collimator Leaf Position Error Determined by Picket Fence Test on Gamma Index Value in Patient-Specific Quality Assurance of Volumetric …

C Ceylan, SY Inal, E Senol, B Yilmaz, S Sahin - Cureus, 2021 - ncbi.nlm.nih.gov
Aim The correlation between the MLC QA (IBA Dosimetry, Germany) results of the picket
fence test created with intentional errors and the patient's quality assurance (QA) evaluation …

Error detection sensitivity test using complex errors on three patient-specific VMAT QA systems

S Thongsawad, S Srisatit… - Journal of Physics …, 2019 - iopscience.iop.org
The purpose of this study was to investigate error detection sensitivity for three patient-
specific volumetric modulated arc therapy (VMAT) quality assurance (QA) systems (Delta 4 …