Numerical analysis of blood damage potential of the HeartMate II and HeartWare HVAD rotary blood pumps
B Thamsen, B Blümel, J Schaller… - Artificial …, 2015 - Wiley Online Library
Implantable left ventricular assist devices (LVAD s) became the therapy of choice in treating
end‐stage heart failure. Although survival improved substantially and is similar in currently …
end‐stage heart failure. Although survival improved substantially and is similar in currently …
Computational characterization of flow and blood damage potential of the new maglev CH-VAD pump versus the HVAD and HeartMate II pumps
Left ventricular assist devices are routinely used to treat patients with advanced heart failure
as a bridge to transplant or a destination therapy. However, non-physiological shear stress …
as a bridge to transplant or a destination therapy. However, non-physiological shear stress …
A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump
A Arvand, M Hormes, H Reul - Artificial Organs, 2005 - Wiley Online Library
A major part of developing rotary blood pumps requires the optimization of hemolytic
properties of the entire pump. Application of a suited computational fluid dynamics (CFD) …
properties of the entire pump. Application of a suited computational fluid dynamics (CFD) …
Computational fluid dynamics analysis of an intra‐cardiac axial flow pump
A Mitoh, T Yano, K Sekine, Y Mitamura… - Artificial …, 2003 - Wiley Online Library
A low rate of hemolysis is an important factor for the development of a rotary blood pump. It
is, however, difficult to identify the areas where hemolysis occurs. Computational fluid …
is, however, difficult to identify the areas where hemolysis occurs. Computational fluid …
Hydraulic characterization of implantable rotary blood pumps
S Boës, B Thamsen, M Haas… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
Objective: The hydraulic properties of implantable rotary blood pumps (RBPs) determine
their interaction with the cardiovascular system. A systematic comparison in this regard has …
their interaction with the cardiovascular system. A systematic comparison in this regard has …
Minimization of hemolysis in centrifugal blood pumps: influence of different geometries
H Schima, MR Müller, D Papantonis… - … Journal of Artificial …, 1993 - journals.sagepub.com
Centrifugal blood pumps are of substantial importance for intraoperative extracorporeal
circulation and for temporary cardiac assist. Their development and improvement raises …
circulation and for temporary cardiac assist. Their development and improvement raises …
A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index
Ventricular assist devices (VADs) have already helped many patients with heart failure but
have the potential to assist more patients if current problems with blood damage (hemolysis …
have the potential to assist more patients if current problems with blood damage (hemolysis …
Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump
J Zhang, B Gellman, A Koert, KA Dasse… - Artificial …, 2006 - Wiley Online Library
The CentriMag centrifugal blood pump is a newly developed ventricular assist device based
on magnetically levitated bearingless rotor technology. A combined computational and …
on magnetically levitated bearingless rotor technology. A combined computational and …
The use of computational fluid dynamics in the development of ventricular assist devices
Progress in the field of prosthetic cardiovascular devices has significantly contributed to the
rapid advancements in cardiac therapy during the last four decades. The concept of …
rapid advancements in cardiac therapy during the last four decades. The concept of …
Development of Design Methods of a Centrifugal Blood Pump with In Vitro Tests, Flow Visualization, and Computational Fluid Dynamics: Results inHemolysis Tests
K Takiura, T Masuzawa, S Endo, Y Wakisaka… - Artificial …, 1998 - Wiley Online Library
There are few established engineering guidelines aimed at reducing hemolysis for the
design of centrifugal blood pumps. In this study, a fluid dynamic approach was applied to …
design of centrifugal blood pumps. In this study, a fluid dynamic approach was applied to …