Numerical analysis of blood damage potential of the HeartMate II and HeartWare HVAD rotary blood pumps

B Thamsen, B Blümel, J Schaller… - Artificial …, 2015 - Wiley Online Library
Implantable left ventricular assist devices (LVAD s) became the therapy of choice in treating
end‐stage heart failure. Although survival improved substantially and is similar in currently …

Computational characterization of flow and blood damage potential of the new maglev CH-VAD pump versus the HVAD and HeartMate II pumps

J Zhang, Z Chen, BP Griffith… - The International journal …, 2020 - journals.sagepub.com
Left ventricular assist devices are routinely used to treat patients with advanced heart failure
as a bridge to transplant or a destination therapy. However, non-physiological shear stress …

A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump

A Arvand, M Hormes, H Reul - Artificial Organs, 2005 - Wiley Online Library
A major part of developing rotary blood pumps requires the optimization of hemolytic
properties of the entire pump. Application of a suited computational fluid dynamics (CFD) …

Computational fluid dynamics analysis of an intra‐cardiac axial flow pump

A Mitoh, T Yano, K Sekine, Y Mitamura… - Artificial …, 2003 - Wiley Online Library
A low rate of hemolysis is an important factor for the development of a rotary blood pump. It
is, however, difficult to identify the areas where hemolysis occurs. Computational fluid …

Hydraulic characterization of implantable rotary blood pumps

S Boës, B Thamsen, M Haas… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
Objective: The hydraulic properties of implantable rotary blood pumps (RBPs) determine
their interaction with the cardiovascular system. A systematic comparison in this regard has …

Minimization of hemolysis in centrifugal blood pumps: influence of different geometries

H Schima, MR Müller, D Papantonis… - … Journal of Artificial …, 1993 - journals.sagepub.com
Centrifugal blood pumps are of substantial importance for intraoperative extracorporeal
circulation and for temporary cardiac assist. Their development and improvement raises …

A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index

KH Fraser, T Zhang, ME Taskin, BP Griffith, ZJ Wu - 2012 - asmedigitalcollection.asme.org
Ventricular assist devices (VADs) have already helped many patients with heart failure but
have the potential to assist more patients if current problems with blood damage (hemolysis …

Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump

J Zhang, B Gellman, A Koert, KA Dasse… - Artificial …, 2006 - Wiley Online Library
The CentriMag centrifugal blood pump is a newly developed ventricular assist device based
on magnetically levitated bearingless rotor technology. A combined computational and …

The use of computational fluid dynamics in the development of ventricular assist devices

KH Fraser, ME Taskin, BP Griffith, ZJ Wu - Medical engineering & physics, 2011 - Elsevier
Progress in the field of prosthetic cardiovascular devices has significantly contributed to the
rapid advancements in cardiac therapy during the last four decades. The concept of …

Development of Design Methods of a Centrifugal Blood Pump with In Vitro Tests, Flow Visualization, and Computational Fluid Dynamics: Results inHemolysis Tests

K Takiura, T Masuzawa, S Endo, Y Wakisaka… - Artificial …, 1998 - Wiley Online Library
There are few established engineering guidelines aimed at reducing hemolysis for the
design of centrifugal blood pumps. In this study, a fluid dynamic approach was applied to …