Image-based decision-making treatment of degenerated mitroflow and trifecta prostheses

A Van Linden, J Blumenstein, H Möllmann… - The Annals of Thoracic …, 2014 - Elsevier
Purpose In the present report we describe our clinical experience using specific image-
based decision making and anatomic considerations for transcatheter valve-in-valve (ViV) …

Redo procedures for degenerated stentless aortic xenografts and the role of valve-in-valve transcatheter techniques

H Grubitzsch, S Zobel, T Christ… - European Journal of …, 2017 - academic.oup.com
OBJECTIVES: This study evaluates reinterventions for degenerated stentless aortic
xenografts. METHODS: Between 2010 and 2015, 52 consecutive patients (age 72.3±9.7 …

Feasibility of Valve-in-Valve Procedure for Degenerated St. Jude Medical Trifecta Bioprosthesis.

JP Verhoye, M Harmouche, RB Soulami… - The Journal of Heart …, 2015 - europepmc.org
The valve-in-valve (ViV) procedure is an option for patients with symptomatic structural
degeneration of a bioprosthesis and excessive reoperative risk. The risk of coronary …

[HTML][HTML] The challenge of valve-in-valve procedures in degenerated Mitroflow bioprostheses and the advantage of using the JenaValve transcatheter heart valve

L Conradi, B Kloth, M Seiffert… - …, 2014 - eurointervention.pcronline.com
Aims: Recently, the feasibility of valve-in-valve procedures using current first-generation
transcatheter heart valves (THV) in cases of structural valve degeneration has been reported …

Valve-in-valve procedures in failing biological xenografts using a novel balloon-expandable device: experience in aortic, mitral, and tricuspid positions

A Schaefer, L Conradi, M Seiffert… - The Thoracic and …, 2015 - thieme-connect.com
Background Valve-in-valve (ViV) procedures for degenerated bioprostheses are an
alternative for the standard of care in an aging population. Several reports showed that the …

Efficacy and safety of transcatheter valve‐in‐valve replacement for Mitroflow bioprosthetic valve dysfunction

VX Mosquera, M González‐Barbeito… - Journal of Cardiac …, 2018 - Wiley Online Library
Objectives Bioprostheses with pericardial leaflets mounted externally on the stent pose a
high risk for valve‐in‐valve (ViV) procedures. This study analyzed the efficacy and safety of …

Early structural valve deterioration of the Mitroflow aortic bioprosthesis

T Kaneko, I Gosev, M Leacche, JG Byrne - Circulation, 2014 - Am Heart Assoc
1998 Circulation December 2, 2014 echocardiogram was used to follow up these patients,
and an increased gradient and valve insufficiency were used as the criteria for SVD. Only …

Transcatheter valve-in-valve implantation in a degenerated very small Mitroflow prosthesis

S Lopez, P Meyer, J Teboul, P Deharo… - Interactive …, 2018 - academic.oup.com
OBJECTIVES To assess the feasibility and results of 'valve-in-valve'implantation using the
23-mm CoreValve for the treatment of degenerated 19-mm and 21-mm Mitroflow …

[HTML][HTML] Sudden death after valve-in-valve procedure due to delayed coronary obstruction: a case report

A Buscaglia, G Tini, GP Bezante, C Brunelli… - Journal of Medical Case …, 2018 - Springer
Background Valve-in-valve transcatheter aortic valve implantation for degenerated aortic
bioprostheses is an effective option for patients at high risk for redo surgery, even if it may be …

Transapical off-pump valve-in-valve implantation in patients with degenerated aortic xenografts

J Kempfert, A Van Linden, A Linke, MA Borger… - The Annals of thoracic …, 2010 - Elsevier
BACKGROUND: The reoperative risk for degenerated aortic valve xenografts may be
increased in elderly patients with comorbidities. We evaluated the off-pump beating heart …