Quantification of neonatal lung parenchymal density via ultrashort echo time MRI with comparison to CT
Purpose To demonstrate that ultrashort echo time (UTE) magnetic resonance imaging (MRI)
can achieve computed tomography (CT)‐like quantification of lung parenchyma in free …
can achieve computed tomography (CT)‐like quantification of lung parenchyma in free …
Pulmonary MRI of neonates in the intensive care unit using 3D ultrashort echo time and a small footprint MRI system
Purpose To determine the feasibility of pulmonary magnetic resonance imaging (MRI) of
neonatal lung structures enabled by combining two novel technologies: first, a 3D radial …
neonatal lung structures enabled by combining two novel technologies: first, a 3D radial …
Structure-function imaging of lung disease using ultrashort echo time MRI
Rationale and Objectives: The purpose of this review is to acquaint the reader with recent
advances in ultrashort echo time (UTE) magnetic resonance imaging (MRI) of the lung and …
advances in ultrashort echo time (UTE) magnetic resonance imaging (MRI) of the lung and …
Ultrashort echo time MRI of the lung in children and adolescents: comparison with non-enhanced computed tomography and standard post-contrast T1w MRI …
DM Renz, KH Herrmann, M Kraemer, J Boettcher… - European …, 2022 - Springer
Objectives To compare the diagnostic value of ultrashort echo time (UTE) magnetic
resonance imaging (MRI) for the lung versus the gold standard computed tomography (CT) …
resonance imaging (MRI) for the lung versus the gold standard computed tomography (CT) …
Clinical feasibility of structural and functional MRI in free‐breathing neonates and infants
B Zanette, EM Schrauben, S Munidasa… - Journal of Magnetic …, 2022 - Wiley Online Library
Background Evaluation of structural lung abnormalities with magnetic resonance imaging
(MRI) has previously been shown to be predictive of clinical neonatal outcomes in preterm …
(MRI) has previously been shown to be predictive of clinical neonatal outcomes in preterm …
[HTML][HTML] Clinical application of ultrashort echo-time MRI for lung pathologies in children
Lung magnetic resonance imaging (MRI) is considered to be challenging, because the low
proton density of the tissue, fast signal decay, and respiratory artefacts hamper adequate …
proton density of the tissue, fast signal decay, and respiratory artefacts hamper adequate …
Three‐dimensional assessment of lung tissue density using a clinical ultrashort echo time at 3 tesla: a feasibility study in healthy subjects
M Lederlin, Y Crémillieux - Journal of Magnetic Resonance …, 2014 - Wiley Online Library
Purpose To implement and assess the performance of three‐dimensional (3D) ultra‐short
echo (UTE) time for evaluating lung tissue density changes induced by gravity dependence …
echo (UTE) time for evaluating lung tissue density changes induced by gravity dependence …
Fetal MRI radiomics: non-invasive and reproducible quantification of human lung maturity
F Prayer, ML Watzenböck, BH Heidinger, J Rainer… - European …, 2023 - Springer
Objectives To assess the reproducibility of radiomics features extracted from the developing
lung in repeated in-vivo fetal MRI acquisitions. Methods In-vivo MRI (1.5 Tesla) scans of 30 …
lung in repeated in-vivo fetal MRI acquisitions. Methods In-vivo MRI (1.5 Tesla) scans of 30 …
Elevated lung volumes in neonates with bronchopulmonary dysplasia measured via MRI
LM Yoder, NS Higano, AH Schapiro… - Pediatric …, 2019 - Wiley Online Library
Background Bronchopulmonary dysplasia (BPD) is a chronic lung disease of prematurity
defined by requirement for respiratory support at 36 weeks postmenstrual age (PMA), but …
defined by requirement for respiratory support at 36 weeks postmenstrual age (PMA), but …
Ultrashort echo time (UTE) MRI of the lung: assessment of tissue density in the lung parenchyma
O Togao, R Tsuji, Y Ohno, I Dimitrov… - Magnetic resonance …, 2010 - Wiley Online Library
Nonuniform disruption of lung architecture is usually assessed by CT, which carries potential
radiation risk. Here we report our use of a three‐dimensional ultrashort echo time MR …
radiation risk. Here we report our use of a three‐dimensional ultrashort echo time MR …