PT-SAFE: A software tool for development and annunciation of medical audible alarms

CL Bennett, RR McNeer - Anesthesia & Analgesia, 2012 - journals.lww.com
BACKGROUND: Recent reports by The Joint Commission as well as the Anesthesia Patient
Safety Foundation have indicated that medical audible alarm effectiveness needs to be …

“For if the trumpet give an uncertain sound, who shall prepare himself to the battle?”(I Corinthians 14: 8, KJV)

FE Block Jr - Anesthesia & Analgesia, 2008 - journals.lww.com
Every clinician is well aware of the problems with audible alarms: False alarms, loud alarms,
difficulty determining what is alarming, and inability to quiet an alarm all create distractions …

Optimization of alarms: a study on alarm limits, alarm sounds, and false alarms, intended to reduce annoyance

FE Block, L Nuutinen, B Ballast - Journal of clinical monitoring and …, 1999 - Springer
Alarms in the operating room remain a major source of annoyance and confusion. Nearly all
alarms result from a transgression of certain alarm limits. We surveyed manufacturers at a …

[引用][C] Audible medical alarms

JR Edworthy, JD Edworthy - Anaesthesia, 2015 - Wiley Online Library
It is encouraging to see Atyeo and Sanderson's article [1] demonstrating that alarm sounds
intended to support a previous version of IEC 60601-1-8 (ISO 9703-2), developed almost 30 …

Measuring the performance of audible alarms for anaesthesia

S Williams, PCW Beatty - Physiological Measurement, 2005 - iopscience.iop.org
The ergonomic performance of an integrated set of 17 audible alarm sounds, divided into
low, medium and high priority classes (Block et al 2000 J. Clin. Monit. Comput. 16 541–6) …

Auditory alarms during anesthesia monitoring with an integrated monitoring system

FE Block, C Schaaf - International journal of clinical monitoring and …, 1996 - Springer
Alarms in the operating room remain a major source of annoyance and confusion. A
previous study by Kestin et al. utilized a specific combination of distinct, separate monitors in …

Auditory icon alarms are more accurately and quickly identified than current standard melodic alarms in a simulated clinical setting

RR McNeer, DB Horn, CL Bennett, JR Edworthy… - …, 2018 - pubs.asahq.org
Background Current standard audible medical alarms are difficult to learn and distinguish
from one another. Auditory icons represent a new type of alarm that has been shown to be …

Medical audible alarms: a review

J Edworthy - Journal of the American Medical Informatics …, 2013 - academic.oup.com
Objectives This paper summarizes much of the research that is applicable to the design of
auditory alarms in a medical context. It also summarizes research that demonstrates that …

Anesthesia alarms in context: an observational study

FJ Seagull, PM Sanderson - Human Factors, 2001 - journals.sagepub.com
This paper surveys current work on the design of alarms for anesthesia environments and
notes some of the problems arising from the need to interpret alarms in context. Anesthetists' …

[引用][C] Current equipment alarm sounds: friend or foe?

S Dain - Canadian Journal of Anesthesia, 2003 - search.proquest.com
T equipment, that from the outside appearance look the same, could have very different